12V
DC
Battery
+
-
Relay Module
N.O. N.C. C
+
_
+
-
24V
DC
Power supply
(Max 28V)
~
~
16/24V
AC
Power supply
or
23
24 25
26 27
28
19 20
21 22
29 30
31 32
3
4
5
6
7
8
9
10 11 12
13 14 15
16 17 18
1
2
C
C
C
C
C
C
C
C
C
C
C
INPUT
INPUT
INPUT
INPUT
INPUT
INPUT
C
16 / 24 Vac
AUX
Zone Labels
Space is provided to label each zone.
Zone Connections
Connect detection devices
as described in “Hardwired
Zone Inputs” in the Imperial
Reference and Installation
manual.
Use
supplied
battery
cable.
Detachable
Terminals
Pry with
screwdriver if
necessary.
External Module
Tamper Switch
(N.C.)
The ZX32D 32-zone Expansion Module connects to the
Imperial control panel’s Combus and acts as an interface
between the control panel and any hardwired detection
devices. The ZX32D also includes an external 16/24Vac
or 24Vdc power supply input that can be used to power
connected devices.
Compatibility
Installation
The ZX32D is a
standard 35mm DIN
rail module. Using the
supplied DIN rail, the
ZX32D can be
mounted in any
location. Alternatively,
it can be mounted in
a standard DIN rail
enclosure. To attach
the module, align the
top of the DIN rail as
shown in Figure 1 and apply pressure to the module until
it clicks into place. To remove the ZX32D from a DIN rail,
pull the release clip and remove the module.
To facilitate installation and servicing, the ZX32D
terminals can be detached from the module. Wires can
be labeled using the supplied tie wraps.
NOTE: The ZX32D does not support ATZ zone doubling.
Upgrading the Firmware
The ZX32D firmware can be upgraded through WinLoad
using the CV4USB RS-485/RS-232 Converter. Refer to
the firmware upgrade instructions found at: paradox.com
- Software - WinLoad - Firmware Upgrade Instructions
EVO48, EVO192
DGP-848, DGP-NE96, EVO96
Figure 1: DIN Rail Mounting
Release
clip
35mm
DIN rail
LOC Button
The ZX32D LOC button is used to enter Test Mode (see page 2).
A Module Locate can be performed using section [4002] (EVO) or [952] (DGP-48
/ DGP-848). To end a module locate, press and hold LOC for 2 seconds.
Manual Controls
The ZX32D supplies 1A to power security system modules. By pressing the AUX
button, the 13.8Vdc auxiliary power supply can be manually activated (LED green)
or deactivated (LED off), allowing modules to be powered down without shutting
down the control panel. If input power is lost, the AUX buttons will stop functioning.
When power is restored, the button will resume its previous state.
ZX32D-EI01
PARADOX.COM
Printed in Canada - 11/2008
Instructions
ZX32D
32-Zone Expansion Module V1.0
Communication LED Feedback
BUS
RX
(from panel)
TX
(to panel)
Condition
green
green flash
green flash
OK (panel communication in progress)
red on
off
off
Short on GRN or YEL
red on
off
green
Communication failure / Too many
modules on bus
red on
green
green
Bus lines reversed (GRN / YEL)
red flash off
off
Bus power too low
red flash green flash
green flash
Locate mode
blue flash off
off
Firmware upgrade in progress
Power LED Feedback
LED
Colour
Condition
AC
green on
AC or DC power is supplied
CHRG green on
Battery is low / charging
BATT green on (less than 4 sec.) Battery test
Zone LED Feedback
LED
Status
off
zone closed
red
zone open
red flash
zone tamper