Summary of Contents for SPECTRA 1727

Page 1: ...SPECTRA 1727 USER S GUIDE...

Page 2: ......

Page 3: ...6 2 3 Zone Display 6 2 4 Alarm Memory Display 6 3 0 PROGRAMMING ACCESS CODES 7 3 1 System Master Code 7 3 2 Programming Access Codes 7 4 0 ARMING DISARMING 9 4 1 Exit Delay 9 4 2 Disarming Deactivati...

Page 4: ...ide 5 0 ADDITIONAL FEATURES 14 5 1 Programming Chime Zones 14 5 2 Keypad Muting 15 5 3 Panic Alarms 15 5 4 PGM Button Programmable Outputs 15 6 0 FIRE ALARMS 16 7 0 TESTING MAINTENANCE 18 8 0 SYSTEM C...

Page 5: ...se without memorizing complex and confusing codes The system consists of the Spectra Control Panel one Spectra Keypad and various devices such as motion detectors door contacts sirens and lights The e...

Page 6: ...tion will be cancelled Refer to System Checklist in section 8 0 for details 2 1 AUDITORY FEEDBACK When you enter information on the keypad it will guide you with beep tones that communicate acceptance...

Page 7: ...Spectra 1727 5 Figure 2 1 Overview of the LED Keypad...

Page 8: ...button s light is off extinguished the corresponding zone is closed If a button s light is on illuminated the corresponding zone is open i e open door movement detected etc 2 4 ALARM MEMORY DISPLAY If...

Page 9: ...page 8 3 1 SYSTEM MASTER CODE The System Master Code can arm or disarm the system using any of the methods described in section 4 0 and can create modify or delete any User Access Code see section 3 2...

Page 10: ...e Table below 4 Enter a new 4 or 6 digit ACCESS CODE ENTER flashes Return to step 3 to program another code 5 Press CLEAR to exit Section User Code Change Code Regular Arm Can Disarm Bypass Arm Stay A...

Page 11: ...flash during the Exit Delay and the keypad may beep 4 2 DISARMING DEACTIVATING AN ALARM To disarm an armed system or an alarm enter your access code An entry point like the front door will be programm...

Page 12: ...section 4 7 4 4 STAY ARMING This method allows you to remain in the protected area while partially arming the system Certain zones are programmed as Stay Zones which are bypassed when Stay Arming For...

Page 13: ...without waiting for all zones in the system to close Certain zones are programmed as Bypass Enabled Zones which are bypassed when Force Arming When Force Arming a Bypass Enabled Zone is considered dea...

Page 14: ...rtain zones when you are renovating The Fire Zone and zones that are not Bypass Enabled by your installer cannot be bypassed How Do I Force Arm 1 Close all zones except Bypass Enabled Zones 2 Press th...

Page 15: ...feature to allow specific individuals like service personnel i e cleaners to arm without giving them access to any other alarm system operations For details on Regular Arming see section 4 3 For detai...

Page 16: ...nabled for that keypad If the keypad emits a Rejection Beep these features have been disabled 5 1 PROGRAMMING CHIME ZONES This feature allows you to program which zones will be Chime Enabled A Chime E...

Page 17: ...em can provide a panic alarm that can immediately generate an alarm after simultaneously pressing and holding the 1 and 3 buttons for two seconds 5 4 PGM BUTTON PROGRAMMABLE OUTPUTS Your Spectra 1727...

Page 18: ...lure of stoves or ovens Careless smoking is the leading cause of fire deaths Smoke detectors and smolder resistant bedding and upholstered furniture are significant fire deterrents Heating is the seco...

Page 19: ...covered Never return to a burning building for any reason it may cost you your life Having at least one working smoke alarm dramatically increases your chances of surviving a fire Remember to practic...

Page 20: ...inates Do not use an open flame or burning materials to test your fire detection devices Your installer can advise you of the best way to test your particular system Under normal use your system requi...

Page 21: ...ES For details see section 3 2 4 Digit Codes l 6 Digit Codes l ONE TOUCH ARMING Press and hold ENTER for two seconds l One touch Arming is Regular Arming l One touch Arming is Stay Arming PANIC ALARMS...

Page 22: ...ors Exit Delay _______sec time to exit site Entry Delay _______sec time to disarm before alarm enter through zone ___________ Alarm will activate siren or bell for ______ min OTHER INFORMATION Install...

Page 23: ...rmance of the security system Seller obligation and liability under this warranty is expressly limited to repairing or replacing at Seller s option any product not meeting the specifications In no eve...

Page 24: ......