66
Programming Guide
WinLoad / BabyWare
Monitoring Phone #
Communicator
Cancel Communication
Step
Action
Details
1
+
[
INSTALLER
CODE
]
= flash.
2
3
[9]
4
[
PHONE
#]
+
[
ENTER
]
*
Enter PC phone # (up to 32 digits) and press [
ENTER
].* To erase WinLoad / BabyWare
phone #, panel ID, and PC password, press the [
SLEEP
] key for 3 seconds.
5
[
PANEL
ID
]
Enter 4-digit Panel ID
6
[
PC
PASSWORD
]
Enter 4-digit PC Password
Step
Action
Details
1
+
[
INSTALLER
CODE
]
= flash.
2
3
[1]
4
[
PHONE
#]
+
[
ENTER
]
*
Enter monitoring station phone # (up to 32 digits) and press [
ENTER
].* To erase monitoring
phone #, reporting format, and account #s, press the [
SLEEP
] key for 3 seconds.
5
[
PARTITION
1
ACCOUNT
#]
6
[1]
= CID
[2]
= SIA
NOTE:
SIA is not supported with GPRS/IP reporting
7
[
PARTITION
2
ACCOUNT
#]
Step
Action
Details
1
+
[
INSTALLER
CODE
]
= flash.
[
MAINTENANCE
CODE
]
may also be used, however, it cannot modify the
backup phone number.
2
3
[2]
= Backup Phone #
[3]
= Personal Phone #1
[4]
= Personal Phone #2
[5]
= Personal Phone #3
[6]
= Personal Phone #4
[7]
= Personal Phone #5
[8]
= Pager #
4
[
PHONE
#]
+
[
ENTER
]
*
Enter phone # (up to 32 digits) and press [
ENTER
]. Goes to next phone#, or go to step 5 if
[8] = Pager # was selected. To erase a phone number pager message, press the [
SLEEP
]
key for 3 seconds.
5
[
MESSAGE
]
+
[
ENTER
]
Step 5 for Pager # only. Enter pager message and press [
ENTER
].
Step
Action
Details
1
+
[
INSTALLER
CODE
]
= flash.
[
MAINTENANCE
CODE
]
may also be used.
2
3
[9]
Cancels all communication with WinLoad / BabyWare / GSM module.
Summary of Contents for MG5050