18
Programming Guide
Zone Report Codes
(Default = FF)
Keypad Programming
Keypad Zone Number Assignment
Entry Point Zone Assignment
(StayD)
Keypad Input/Output Configuration (K636 V2.0 and higher)
NOTE:
When configuring as an output, you must first clear the keypad zone (if assigned).
[966]
Clear Zone Report Codes
Option
OFF
ON
[1]
Clear zone report codes*
Disabled
Enabled
* Ensure all other options are deselected. Press
[
ENTER
]
to clear the respective set of report codes before exiting the section.
[967]
Reset Zone Report Codes
Option
OFF
ON
[1]
Reset zone report codes to default*
Disabled
Enabled
* Ensure all other options are deselected. Press
[
ENTER
]
to reset the respective set of report codes before exiting the section.
Section
Alarm
Alarm
Restore
Tamper
Tamper
Restore
Section
Alarm
Alarm
Restore
Tamper
Tamper
Restore
[141]
Zone 1:
___/___ ___/___ ___/___ ___/___
[157]
Zone 17: ___/___ ___/___ ___/___ ___/___
[142]
Zone 2:
___/___ ___/___ ___/___ ___/___
[158]
Zone 18: ___/___ ___/___ ___/___ ___/___
[143]
Zone 3:
___/___ ___/___ ___/___ ___/___
[159]
Zone 19: ___/___ ___/___ ___/___ ___/___
[144]
Zone 4:
___/___ ___/___ ___/___ ___/___
[160]
Zone 20: ___/___ ___/___ ___/___ ___/___
[145]
Zone 5:
___/___ ___/___ ___/___ ___/___
[161]
Zone 21: ___/___ ___/___ ___/___ ___/___
[146]
Zone 6:
___/___ ___/___ ___/___ ___/___
[162]
Zone 22: ___/___ ___/___ ___/___ ___/___
[147]
Zone 7:
___/___ ___/___ ___/___ ___/___
[163]
Zone 23: ___/___ ___/___ ___/___ ___/___
[148]
Zone 8:
___/___ ___/___ ___/___ ___/___
[164]
Zone 24: ___/___ ___/___ ___/___ ___/___
[149]
Zone 9:
___/___ ___/___ ___/___ ___/___
[165]
Zone 25: ___/___ ___/___ ___/___ ___/___
[150]
Zone 10: ___/___ ___/___ ___/___ ___/___
[166]
Zone 26: ___/___ ___/___ ___/___ ___/___
[151]
Zone 11: ___/___ ___/___ ___/___ ___/___
[167]
Zone 27: ___/___ ___/___ ___/___ ___/___
[152]
Zone 12: ___/___ ___/___ ___/___ ___/___
[168]
Zone 28: ___/___ ___/___ ___/___ ___/___
[153]
Zone 13: ___/___ ___/___ ___/___ ___/___
[169]
Zone 29: ___/___ ___/___ ___/___ ___/___
[154]
Zone 14: ___/___ ___/___ ___/___ ___/___
[170]
Zone 30: ___/___ ___/___ ___/___ ___/___
[155]
Zone 15: ___/___ ___/___ ___/___ ___/___
[171]
Zone 31: ___/___ ___/___ ___/___ ___/___
[156]
Zone 16: ___/___ ___/___ ___/___ ___/___
[172]
Zone 32: ___/___ ___/___ ___/___ ___/___
Step
Action
Details
1
[
ENTER
]
+
[
INSTALLER
CODE
]
(default: 0000 / 000000)
[
ARM
]
+
[
STAY
]
= flash.
[
MAINTENANCE
CODE
]
may also be used.
2
Press and hold
(3sec)
[
ARM
]
+
[
STAY
]
= on.
3
[
ZONE
NUMBER
]
+
[
ENTER
]
K35 / K32 / K32LCD = 2 digits: 01 to 32.
K636 / K10V/H = 1 digit: 1 to 0 (10).
To erase a keypad zone number, press
[
CLEAR
]
, then
[
ENTER
]
.
Step
Action
Details
1
[
ENTER
]
+
[
INSTALLER
CODE
]
(default: 0000 / 000000)
[
ARM
]
+
[
STAY
]
= flash.
2
Press and hold
[
OFF
]
(3sec)
[
ARM
]
+
[
STAY
]
= on.
3
[
ZONE
NUMBER
]
K35 / K32RF / K37 / K32 / K32LCD = 2 digits: 01 to 32.
K636 / K10V/H = 1 digit: 1 to 0(10) (maximum 10 zones).
The first zone you program will be the designated entry point and will flash. Up to three more
path zones can be added; these zones will light up and stay lit.
4
[
ENTER
]
Press
[
ENTER
]
to save and exit.
Step
Action
Details
1
[
ENTER
]
+
[
INSTALLER
CODE
]
(default: 0000 / 000000)
[
ARM
]
+
[
STAY
]
= flash.
2
Press and hold
[
ENTER
]
(3sec)
[
ARM
]
+
[
STAY
]
= on.
3
Option
[1]
ON = Output switches to ground following system arming (Blue wire 150mA max.).
OFF
= Input (Keypad zone input).
4
Option
[2]
ON = Output N.C.
OFF
= Output N.O.
Summary of Contents for MG5050
Page 71: ......