22
Reference & Installation Manual
Arming and Disarming
Regular Arming Switches to Stay Arming
Section [092]: Option [4]
Option [4] OFF = Regular arming switches to Stay arming
disabled (default)
Option [4] ON =
Regular arming switches to Stay arming
enabled
If a user Regular arms the system, but does not exit through
(open and close) an Entry Delay zone during the Exit Delay, the
console can be programmed to switch from Regular arming to
Stay arming.
Regular Arming Switches to Force Arming
Section [092]: Option [5]
Option [5] OFF = Regular arming switches to Force arming
disabled
Option [5] ON =
Regular arming switches to Force arming
enabled (default)
With this feature enabled, the console will always Force arm
instead of Regular arm when a valid User code is entered. In
installations where the user must always Force arm when
leaving the protected area, this feature allows users to Force arm
after entering their User code.
This feature is not for use in UL installations.
Stay Arming Switches to Force Arming
Section [092]: Option [6]
Option [6] OFF = Stay Arming Switches to Force Arming
disabled (default)
Option [6] ON =
Stay Arming Switches to Force Arming
enabled
With this feature enabled, the console will always Force arm and
Stay arm when a valid User code is entered even if there are
perimeter zones open.
This feature is not for use in UL installations.
Timed Auto-Arming
Section [092]: Option [1]
Option [1] OFF = Timed Auto-arming disabled (default)
Option [1] ON =
Timed Auto-arming enabled
The Magellan system can be programmed to arm every day at
the time specified by the Auto-arm Timer (see Auto-arm Timer on
page 22). The following also apply:
•
The Auto-arming options (see Auto-Arming Options on page
23) determine the arming method.
•
Any open zones detected when the system is Auto-armed
will be bypassed regardless of their definition (except 24Hr.
zones).
•
The console will enter a 60-second Exit Delay period before
arming the system. At this point, Auto-arming can be
cancelled by entering a valid Access code.
•
Once the system has successfully armed, the console can
transmit the Timed Auto-Arming report code programmed in
section [124].
Example: To automatically arm the system everyday at 6:15PM,
enable section [092] option [1] to activate Timed Auto-arming
and then key in 18:15 into section [085].
This feature is not for use in UL installations.
Auto-arm Timer
Section [085]
Using the 24-hour clock (i.e., 6:30PM = 18:30), program the time
that you wish the console to attempt to arm the system and/or
send the Late to Close report code.
No Movement Auto-Arming
Section [092]: Option [2]
Option [2] OFF = No Movement Auto-arming disabled (default)
Option [2] ON =
No Movement Auto-arming enabled
If no movement occurs in a zone's protected area for the period
specified by the No Movement Timer (see below), the console
can automatically arm the system.
•
The Auto-arming option (see Auto-Arming Options on page
23) determines the system's arming method.
•
Any open zones detected when the system is Auto-armed
will be bypassed regardless of their definition (except 24Hr.
zones).
•
Upon arming, the console will transmit the No Movement
report code if programmed in section [124].
•
Regardless of whether the system was successfully armed
or not, the console will always transmit the No Movement
report code if programmed in section [124].
•
If No Movement Auto-arming is disabled, the console will
still send the No Movement report code at the time specified
by the No Movement Timer.
Example: To arm the system whenever there is no movement for
a period of 4 hours, enable section [092] option [2] (No
Movement Auto-arming) and then in section [064], enter 016 (16
x 15min. = 240min. = 4 hours).
This feature is not for use in UL installations.
No Movement Timer
Section [064]: 001 to 255 x 15 minutes; 000 = Disabled; Default
= 000
Program the interval of time without movement that you wish the
console to wait before arming and/or sending the No Movement
report code. If No Movement Auto-arming is disabled, the
console can still send the No Movement report code when no
movement has been detected for the period specified by the No
Movement Timer.