Magellan & Spectra SP • Installation Guide
47
Alarm Options
Bell Cut-Off Timer
Section
[747]
= Partition 1,
[748]
= Partition 2
000 = Disabled, 001 to 255 minutes, Default = 4 minutes,
5 minutes minimum for ULC installations
After an audible alarm, the bell or siren will stop upon disarming of the partition or when the Bell Cut-Off Timer has elapsed, whichever comes first.
Recycle Alarm
After the Bell Cut-Off Timer and the Recycle Delay have elapsed, the control panel will re-verify the zone status. If there are any open zones, the control panel will
generate another alarm. In one armed period, the control panel will repeat this sequence the number of times defined by the Recycle Counter.
Recycle Alarm Delay
Section
[714]
000 = disabled, 001 to 255 minutes, Default = Disabled
The Recycle Delay determines the amount of time after Bell Cut-Off that the control panel will wait before re-verifying zone status.
Recycle Alarm Counter
Section
[715]
000 = disabled, 001 to 255, Default = Disabled
The Recycle Counter determines the number of times the control panel will re-verify the zone status after Bell Cut-Off in one armed period.
Tamper Recognition
Zones/RF Module and Keypad/Bus Module Tamper Recognition
Section
[705]
: Tamper Recognition Options
If a device has been tampered with (i.e. the anti-tamper switch has been set off ), the control panel can generate a trouble, an alarm, and/or transmit a report code to
the monitoring station. The system will react to an RF zone and a keypad/bus module differently.
RF Module Supervision
Section
[705]
: Supervision Options
The control panel waits for each of its assigned wireless transmitters to send a status signal within a specified time period to confirm their presence and
functionality. If a device has not sent a signal within that time period, the control panel can generate a trouble, an alarm, and/or transmit a report code to the
monitoring station. The system will react to an RF zone and a keypad/bus module differently.
Tamper Bypass Options
Section
[705]
: Zone Options
Option
[5]
OFF= Tampers on bypassed zones will be ignored
Option
[5]
ON= Will generate a tamper if detected on a bypassed zone (default)
With option
[5]
off, the Tamper Recognition feature follows the zone bypass definition. This means the control panel will ignore any tampers detected on a
bypassed zone. With option
[5]
on, Tamper Recognition ignores the bypass definition. This means the control panel will generate an incident as per Tamper
Recognition settings if a tamper or wire fault occurs on a bypassed zone.
Tamper Supervision on the Bus Module
Section
[700]
: Supervision Options
Option
[7]
OFF= Tamper supervision disabled (default)
Option
[7]
ON= Tamper supervision enabled
When the control panel detects a tamper on a bus module, the control panel can generate an alarm or trouble, unless the Tamper Supervision is disabled.
[3]
[4]
Zones/RF Module Tamper Recognition Options
Keypad / Bus Module Tamper Recognition Options*
OFF
OFF
Disabled disabled
OFF
ON
trouble only
trouble only
ON
OFF
When disarmed: trouble only
When armed: Follow zone’s alarm type
trouble only
ON
ON
When disarmed: audible alarm
When armed: Follow zone’s alarm type
audible alarm
* Tamper recognition of keypad/bus module only if section
[700]
option
[7]
is enabled.
[6]
[7]
RF Supervision Options
Keypad / Bus Module Supervision Options
OFF
OFF
Disabled Disabled
OFF
ON
trouble only
trouble only
ON
OFF
When disarmed: trouble only
When armed: Follow zone’s alarm type
trouble only
ON
ON
When disarmed: audible alarm
When armed: Follow zone’s alarm type
audible alarm