9
IPC10 Replacement
If an IPC10 module may need to be replaced, the following steps should be followed:
1. Remove the existing IPC10 from the rack it is installed on, replace it with the new IPC10 unit, and connect the IPC10 to a POE switch.
2. Configure the new IPC10 by following steps 1-6 (pages 2-6).
Note:
The network configuration of the replacement IPC10 SHALL be the same as the IPC10 that was removed.
The output protocol configuration of the replacement IPC10 SHALL be the same as the IPC10 that was removed
At this point all the accounts will appear in the replacement IPC10 and reporting to the CMS will be resumed.
Specifications
Compatibility
IP180 (Et Wi-Fi), PCS265V8 (LTE), IP150+ FW 6.0 or higher, and Paradox panels with
IP or cellular on-board
Input Voltage
Power over Ethernet: 35-57 VDC, Class 2 device
Account Capacity
5,000 normal or long supervision, 3,000 for high supervision
Supervision
Long: 20 minutes, 10 minutes
Normal (default): 5 minutes
High: 90 seconds
Supervision Message
Offline (E551) and online (R551) despite new events
Power Input
12.5W
Operating Temperature
0°C to +40°C (+32°F to +104°F)
Replacement Recovery
Auto recovery in case of replacement within 5 minutes
Encryption Type
AES 128-bit
Communication Protocol
CID via Sur-Gard MLR2-DG or Ademco
Dimensions
Fits
19” rack 1U
48.26 x 20.3 x 4.2 cm (19 x 8
x 1.65 in)
Warranty
For complete warranty information on this product, please refer to the Limited Warranty Statement found on the Web site www.paradox.com/Terms. or contact your local
distributor. Specifications may change without prior notice.