2
Reference & Installation Manual
Part 2: Installation
2.1
Location and Mounting
Remove the PCB, mounting hardware and keypad from the packaging inside the panel box. The circuit board should not be
mounted into the back of the cabinet until all cables are pulled into the cabinet and prepared for connection. Before mounting the
cabinet, push the four (728 Ultra) or five (738 Ultra) white nylon-mounting studs into the back of the cabinet. Select an installation
site that is not easily accessible to intruders. Leave at least 5cm (2in) around the panel box to permit adequate ventilation and
heat dissipation. The installation site should be dry and close to an AC source, ground connection and telephone line connection.
2.2
Earth Ground
Connect the zone and dialer ground terminals from the control panel to the metallic enclosure and cold water pipe or grounding
rod as per local electrical codes.
For maximum lightning protection, use separate earth grounds for the zone and dialer grounds as shown in
Figure 1. For UL installations, the metallic enclosure must be grounded to the cold water pipe or grounding rod.
Figure 1: Earth Ground Connection
2.3
AC Power
2.3.1
AC Power
Do not use any switch-controlled outlets to power the transformer. Use a 16.5Vac (50-60Hz) transformer with a
minimum 20VA (40VA recommended) rating to provide sufficient AC power. UL/cUL listed systems require a Universal
Model No. UB1640W plug-in transformer. Connect the transformer as shown in Figure 2.The power supply can provide
a maximum of 1.1A for battery charge current.
Do not connect the transformer or the backup battery until all the wiring is completed.
Figure 2: Connecting AC Power
2.3.2
Backup Battery
We recommend connecting a backup battery to power the control panel in case of power loss. UL/cUL installations
require the use of a backup battery. Use a 12Vdc 4Ah/7Ah rechargeable acid/lead or gel cell battery. For UL/cUL
installations use only a 7Ah battery. Connect the backup battery after applying the AC power as shown in Figure 3 on
page 3. When installing the battery, verify proper polarity, as reversed connections will blow the battery fuse. Connect
the red battery lead to the positive battery terminal, and the black battery lead to the negative battery terminal of the
control panel.
Cold water pipe
or grounding rod
Ground clamp
To metallic
enclosure
AWG# 14 single
conductor solid
copper wire
For UL Installations (728 Ultra)
For UL installations,
make sure that only
the
EARTH
ground is
connected.
Cold water pipe
or grounding rod
Ground clamp
TRANSFORMER
16.5Vac, 20VA minimum (40VA recommended)
A.C.
POWER