PARADOX.COM

 

4 to 32 Zone Security Systems

Esprit E55 V2.0
Esprit E65 V2.1

Programming Guide

Always Armed, 
Never Disarmed

Summary of Contents for ESPRIT 728 ULT

Page 1: ...PARADOX COM 4 to 32 Zone Security Systems Esprit E55 V2 0 Esprit E65 V2 1 Programming Guide Always Armed Never Disarmed ...

Page 2: ...ller should use the following guidelines when configuring the system All components of the system should be UL listed for the intended application If used for Fire detection the installer should refer to NFPA Standards 72 Chapter 2 In addition once installation is complete the local fire authority must be notified of the installation WARNING This equipment must be installed and maintained by quali...

Page 3: ...ion 1 is available To use both partitions use a K10V H K32 or K32I keypad Feature Esprit E55 Esprit E65 Esprit 728ULT StayD 3 3 Maximum Zones 32 32 8 On board Zones 4 9 4 Keypad Zones 15 15 2 Partitions 2 2 2 User Codes 32 32 49 PGMs 1 3 1 Event Buffer 256 256 256 Internet TCP IP Communication IP100 3 3 Landline dialer 3 3 Plug In Voice Module VDMP3 3 via GSM only In Field Firmware Upgradeable 3 3...

Page 4: ...a specific feature Press the key corresponding to the desired option This means the option is ON Press the key again to remove the digit thereby turning OFF the option Press the CLEAR key to set all eight options to OFF When the options are set press the ENTER key to save and advance to the next section Important Settings and Modes Section Description 950 Reset all programmable sections to factory...

Page 5: ...ou to program everything except for user codes and communication settings sections 395 397 398 815 816 817 910 and 911 To set the default code go to section 398 on page 31 and refer to section 701 option 1 on page 31 System Master Code Default 1234 123456 The System Master code can use any arming method and can program user codes To change the default code go to section 399 on page 31 and refer to...

Page 6: ...oint Path Zone Path Zone Path Zone Keypad 1 ZX8 ZX8SP Keypad 2 ZX8 ZX8SP Keypad 3 ZX8 ZX8SP Keypad 4 ZX8 ZX8SP Keypad 5 ZX8 ZX8SP Keypad 6 ZX8 ZX8SP Keypad 7 ZX8 ZX8SP Keypad 8 ZX8 ZX8SP Keypad 9 ZX8 ZX8SP Keypad 10 ZX8 ZX8SP Keypad 11 ZX8 ZX8SP Keypad 12 ZX8 ZX8SP Keypad 13 ZX8 ZX8SP Keypad 14 ZX8 ZX8SP Keypad 15 ZX8 ZX8SP ...

Page 7: ...3 Input 1 Panel 1 Zone 13 Input 5 Jumper Zone 13 Input 4 Zone 13 Panel Input 4B Zone 14 Input 2 Zone 14 Input 6 Panel 1 Zone 14 Input 5 Zone 14 Panel Input 5B ZX8 Zone 15 Input 3 Zone 15 Input 7 Zone 15 Input 6 Zone 15 Panel Input 6B Jumper Zone 16 Input 4 Zone 16 Input 8 Zone 16 Input 7 Zone 16 Panel Input 7B Panel 9 Zone 17 Input 5 Zone 17 Input 1 Zone 17 Input 8 Zone 17 Panel Input 8B Zone 18 I...

Page 8: ...low Sleep Full Arm Not Armed Follow Follow 17 24Hr Hold up 07 Follow Full Arm Not Armed Not Armed Follow 18 24Hr Gas 08 Instant Instant Instant Instant 19 24Hr Heat 09 Instant Sleep Full Arm Not Armed Instant Instant 20 24Hr Water 10 Instant Full Arm Not Armed Not Armed Instant 21 24Hr Freeze 18 24Hr Gas Flex Instant Zone will follow the delay at section 720 default is 15 seconds 0 instant zone 19...

Page 9: ...______ _____ _____ ________ 1 2 3 4 5 6 7 8 015 Zone 15 _________________________ _____ _____ ________ 1 2 3 4 5 6 7 8 016 Zone 16 _________________________ _____ _____ ________ 1 2 3 4 5 6 7 8 017 Zone 17 _________________________ _____ _____ ________ 1 2 3 4 5 6 7 8 018 Zone 18 _________________________ _____ _____ ________ 1 2 3 4 5 6 7 8 019 Zone 19 _________________________ _____ _____ ______...

Page 10: ... Zone 6 Speed 047 Zone 7 Z3 with ATZ Z7 ____ ____ ____ 000 to 255 x 10ms Hardwire Zone 7 Speed 048 Zone 8 Z4 with ATZ Z8 ____ ____ ____ 000 to 255 x 10ms Hardwire Zone 8 Speed 049 Zone 9 N A Z9 ____ ____ ____ 000 to 255 x 10ms Hardwire Zone 9 Speed 050 Zone 10 N A Z1 with ATZ ____ ____ ____ 000 to 255 x 10ms Hardwire Zone 10 Speed 051 Zone 11 N A Z2 with ATZ ____ ____ ____ 000 to 255 x 10ms Hardwi...

Page 11: ...__ ___ ___ ___ ___ 159 Zone 19 ___ ___ ___ ___ ___ ___ ___ ___ 144 Zone 4 ___ ___ ___ ___ ___ ___ ___ ___ 160 Zone 20 ___ ___ ___ ___ ___ ___ ___ ___ 145 Zone 5 ___ ___ ___ ___ ___ ___ ___ ___ 161 Zone 21 ___ ___ ___ ___ ___ ___ ___ ___ 146 Zone 6 ___ ___ ___ ___ ___ ___ ___ ___ 162 Zone 22 ___ ___ ___ ___ ___ ___ ___ ___ 147 Zone 7 ___ ___ ___ ___ ___ ___ ___ ___ 163 Zone 23 ___ ___ ___ ___ ___ _...

Page 12: ... K636 1 digit 1 to 0 10 can only assign zones 1 10 The first zone you program will be the designated entry point and will flash Up to three more path zones can be added these zones will light up and stay lit 4 ENTER Press ENTER to save and exit Step Action Details 1 ENTER INSTALLER CODE default 0000 000000 ARM STAY flash 2 Press and hold ARM 3sec ARM STAY on 3 Option 1 ON Output switches to ground...

Page 13: ...n time Disabled N Enabled 2 Auto arm on no movement Disabled N Enabled 3 4 Auto arm arming mode N See Table N See Table 5 Switch to stay arming if no zone entry delay is opened Disabled N Enabled 6 Follow zones become entry delay 2 when delay zone is bypassed Disabled N Enabled 7 8 N A N A N A 742 Partition 2 Options Option OFF ON 1 Auto arm on time Disabled N Enabled 2 Auto arm on no movement Dis...

Page 14: ...03 Arming Disarming Options 1 Option OFF ON 5 Restrict arming on battery failure Disabled N Enabled 6 Restrict arming on tamper failure Zone Bus Module Disabled N Enabled 8 Calling the VDMP3 N Disabled Enabled 704 Arming Disarming Options 2 Option OFF ON 1 Regular arming switches to force arming N Disabled Enabled 2 Stay arming switches to stay force arming N Disabled Enabled 3 Sleep arming switch...

Page 15: ...codes N Disabled Enabled Telephone Line Monitoring TLM Options 1 2 OFF OFF Disabled OFF ON When disarmed Trouble only When armed Trouble only ON OFF When disarmed Trouble only When armed Audible alarm ON ON Silent alarms become Audible alarm Auto Test Report Transmission Options 3 4 Auto Test Report Transmission Options OFF OFF Transmit the test report code every time the days programmed in sectio...

Page 16: ...ed Enabled 7 Call personal tel on parademic alarm N Disabled Enabled 8 Call personal tel on panel power trouble Disabled N Enabled Section Data Description 810 ___ ___ Reporting format TEL1 TEL2 0 Ademco Slow 1 Silent Knight Fast 2 Sescoa 3 Ademco Express 4 Ademco Contact ID default 811 ____ ____ ____ ____ Partition 1 Account number 812 ____ ____ ____ ____ Partition 2 Account number 815 ___ ___ __...

Page 17: ...plies to the Plug In Voice Dialer when using a VDMP3 850 ____ ____ ____ ____ HH MM Auto test report time of day default 00 00 see section 801 options 3 and 4 on page page 13 851 ____ ____ ____ 000 to 255 x 1 minute Armed report delay default 005 852 ____ ____ ____ 000 to 255 x 1 minute Disarmed report delay default 060 901 ____ ____ ____ 000 to 255 rings Number of rings default 008 902 ____ ____ _...

Page 18: ...abled 2 Automatic event buffer transmission N Disabled N Enabled 910 ____ ____ ____ ____ Panel ID NOTE For increased communication security change the default Panel ID and PC password 911 ____ ____ ____ ____ PC password 915 ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ PC TELEPHONE NUMBER 780 ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ SMS ...

Page 19: ...olish 005 Dutch 011 Romanian 017 806 IP GPRS Options E65 panels only Option 5 6 OFF ON 7 Use dialer reporting N As IP GPRS reporting backup N In addition to IP GPRS reporting 8 Enable IP GPRS reporting N Disabled N Enabled GSM Reporting 1 2 Primary Backup OFF OFF Landline Landline OFF ON Landline GSM ON OFF GSM Landline ON ON GSM GSM Options 1 and 2 are only available on the E55 control panel The ...

Page 20: ...34 ___ ___ IP PROFILE E G 01 935 IP RECEIVER STATUS VIEW STATUS TO REGISTER PRESS ARM 936 ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ IP ADDRESS WAN1 E G 100 100 100 100 937 ___ ___ ___ ___ ___ IP PORT WAN1 E G 10000 938 ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ IP ADDRESS WAN2 939 ___ ___ ___ ___ ___ IP PORT WAN2 940 ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ IP PAS...

Page 21: ... to register module Section Event Group Sub Group Partition 99 for any partitions Default 220 PGM 1 Activation Event ____ ____ ____ ____ ____ ____ 00 00 00 221 Deactivation Event ____ ____ ____ ____ ____ ____ 00 00 00 222 PGM 2 Activation Event ____ ____ ____ ____ ____ ____ 00 00 00 223 Deactivation Event ____ ____ ____ ____ ____ ____ 00 00 00 224 PGM 3 Activation Event ____ ____ ____ ____ ____ __...

Page 22: ...ail to communicate Partition 1 only 08 Utility Key 1 pressed keys 1 and 2 Partition 1 only 09 Utility Key 2 pressed keys 4 and 5 Partition 1 only 10 Utility Key 3 pressed keys 7 and 8 Partition 1 only 11 Utility Key 4 pressed keys 2 and 3 Partition 1 only 12 Utility Key 5 pressed keys 5 and 6 Partition 1 only 13 Utility Key 6 pressed keys 8 and 9 Partition 1 only 14 Tamper generated alarm 15 Super...

Page 23: ...ng through WinLoad 06 Arming with keyswitch 99 Any special arming 31 Disarming with user 01 to 32 User number 99 Any user number 32 Disarming after alarm with user 33 Alarm cancelled with user 34 Special disarming 00 Auto arm cancelled on time no movement 01 Disarming through WinLoad 02 Disarming through WinLoad after alarm 03 Alarm cancelled through WinLoad 04 N A 05 Disarm with keyswitch 06 Disa...

Page 24: ... loop trouble restore 08 FTC central 1 restored 09 FTC central 2 restored 10 FTC pager restored 11 FTC voice restored 13 GSM jamming restored 14 GSM no service restore 15 GSM supervision lost restore 16 Fail To Communicate restore IP Receiver 1 GPRS E65 only 17 Fail To Communicate restore IP Receiver 2 GPRS E65 only 18 IP Module No Service restore E65 panels only 19 IP Module Supervision loss rest...

Page 25: ...M Base Time Off Sec On Min N N N 2 PGM State Off N O On N C N N N 3 N A N A N A N A N A N A N A 4 PGM Activation Mode Off Steady On Pulse N N N 5 PGM Pulse once every 30 seconds if armed N N N 6 PGM Pulse on any alarm N N N 7 PGM Pulse on any alarm Off Partition 1 On Partition 2 N N N 8 Voltage Output E65 PGMs only Off Negative Trigger 0V On Positive Trigger 12V N N N ZX8 1 ZX8 9 ZX8 17 PGM4 PGM 6...

Page 26: ...ZX8 ID 17 ___ ___ ___ 000 to 255 x 1 sec mins 289 PGM 9 PGM4 output 1 ___ ___ ___ 000 to 255 x 1 sec mins 290 PGM 10 PGM4 output 2 ___ ___ ___ 000 to 255 x 1 sec mins 291 PGM 11 PGM4 output 3 ___ ___ ___ 000 to 255 x 1 sec mins 292 PGM 12 PGM4 output 4 ___ ___ ___ 000 to 255 x 1 sec mins 966 Clear Report Codes Option OFF ON 3 Clear arm disarm alarm report codes N Disabled N Enabled 4 Clear trouble...

Page 27: ...____ ____ N A 868 ____ ____ Module power fail ____ ____ AC failure ____ ____ Module low no battery ____ ____ Battery failure ____ ____ N A ____ ____ Auxiliary supply ____ ____ N A 866 ____ ____ Bell output overload ____ ____ Bell output disconnect ____ ____ Timer loss ____ ____ N A 867 ____ ____ Fail to communicate ____ ____ N A ____ ____ Module lost ____ ____ Module tamper Section Data Descriptio...

Page 28: ... 338 Exp module low battery 57 116 Duct 0A 163 Tank level 31 339 Exp module reset 58 117 Flame 0B Fire Supervisory 200 and 210 341 Exp module tamper 59 118 Near alarm 0C 200 Fire supervisory 32 342 Exp module AC loss 5A Panic Alarms 120 201 Low water pressure 33 343 Exp module self test fail 5B 120 Panic Alarm 0D 202 Low CO2 34 344 RF receiver jam detect 5C 121 Duress 0E 203 Gate valve sensor 35 C...

Page 29: ... on premises A1 611 Point test OK C6 401 Open Close by user 7C 459 Recent close A2 612 Point not tested C7 402 Group open close 7D System 460 613 Intrusion zone walk tested C8 403 Automatic open close 7E 461 Wrong code entry A3 614 Fire zone walk tested C9 462 Legal code entry A4 615 Panic zone walk tested CA 463 Re arm after alarm A5 616 Service request CB 406 Cancel 7F 464 Auto arm time extended...

Page 30: ...ass Quick arming 3 4A8 Quick arm Arm with PC software 3 4A7 Remote arm disarm Disarm with User Code 1 4A1 Open by user Disarm after alarm with User Code 1 4A1 Open by user Cancel alarm with User Code 1 4A6 Cancel by user Auto arming cancellation 1 464 Deferred open close Disarm with PC software 1 4A7 Remote arm disarm Disarm after an alarm with PC software 1 4A7 Remote arm disarm Cancel alarm with...

Page 31: ... 3 333 Expansion module failure restore Module tamper restore 3 341 Expansion module tamper restore Cold start 1 3A8 System shutdown Test report engaged 1 6A2 Periodic test report PC software communication finished 1 412 Successful download access Installer on site 1 627 Program mode entry Installer programming finished 1 628 Program mode exit Maintenance in 1 627 Program mode entry Maintenance ou...

Page 32: ...in Menu Trouble Sub Menu Trouble Menu 2 Power trouble 1 Low No battery on the control panel 2 AC failure on control panel 3 Auxiliary overload on control panel 8 Low power on GSM communication module 3 Bell trouble 1 Bell disconnect on control panel 2 Bell overload on control panel 4 Communication trouble 1 Telephone Line Monitoring on control panel 2 Fail to communicate on Monitoring Telephone 1 ...

Page 33: ...7 Backup monitoring station telephone 397 Installer code 910 Panel ID 398 Maintenance code 911 PC password 815 Monitoring station telephone number 1 970 Download memory key into panel 816 Monitoring station telephone number 2 975 Upload panel into the memory key User Options 1 Partition 1 Access 5 Force Arming Regular Sleep StayArming 2 Partition 2 Access 6 Arm Only 3 Bypass Programming 7 PGM Acti...

Page 34: ... ____ 488 User 18 ____ ____ ____ ____ 473 Master 2 ____ ____ ____ ____ 489 User 19 ____ ____ ____ ____ 474 User 4 ____ ____ ____ ____ 490 User 20 ____ ____ ____ ____ 475 User 5 ____ ____ ____ ____ 491 User 21 ____ ____ ____ ____ 476 User 6 ____ ____ ____ ____ 492 User 22 ____ ____ ____ ____ 477 User 7 ____ ____ ____ ____ 493 User 23 ____ ____ ____ ____ 478 User 8 ____ ____ ____ ____ 494 User 24 __...

Page 35: ...Esprit E55 E65 33 Hardware Connections Single Zone Inputs NOTE Keyswitches are connected as standard zones and will follow ATZ options programmed in section 705 options 1 and 2 on page 8 ...

Page 36: ...34 Programming Guide Advanced Technology Zone ATZ Connections ...

Page 37: ...mum of E55 450mA fuseless shutdown at 650mA E65 500mA fuseless shutdown at 700mA Acceptable Battery Charge Current 1 1A Single Fire Zone Connections Only If the ATZ feature is enabled do not use the extra input i e in the above example input 005 cannot be used as a zone PGM Power Source AUX terminal E55 current consumption must not exceed 450mA E65 current consumption must not exceed 500mA Externa...

Page 38: ... new updates click the Download Firmware from the web button 7 From the Select Firmware drop down box select the firmware version you wish to install or If you have already downloaded the pef file from paradox com click the button and select the location of the pef file 8 Click the Update product firmware button 9 When the download process finishes the update is complete Metal Box Installation The...

Page 39: ...d the panel power supply and lead to complete system shutdown The BELL output will shutdown if the current exceeds 3A To provide maximum lightning protection we strongly recommend having separate earth connections for the dialer and zone ground terminals Max number of keypads 15 keypads Max aux current 650 mA Max distance of keypad from panel 76m 250 feet Max total run of wire 230m 750 feet For th...

Page 40: ... this limit will overload the panel power supply and lead to complete system shutdown The BELL output will shutdown if the current exceeds 3A Max number of keypads 15 keypads Max aux current 700 mA Max distance of keypad from panel 76m 250 feet Max total run of wire 230m 750 feet For the keypad s zone configurations refer to the Installer Quick Menu If EOL is enabled see section 706 option 2 Also ...

Page 41: ...one to one or both partitions and press ENTER By default all zones are assigned to partition 1 Goes to next available zone Step Action Details 1 ENTER INSTALLER CODE ARM STAY flash MAINTENANCE CODE may also be used 2 Press and hold 3sec ARM STAY on 3 ZONE NUMBER ENTER K32LED K32I 2 digits 01 to 32 K10V H K636 1 digit 1 to 0 10 can only assign zones 1 10 To erase a keypad zone number press CLEAR th...

Page 42: ...ds 5 CONFIRM CODE Re enter 4 or 6 digit code Step Action Details 1 INSTALLER CODE flash 2 3 9 4 PHONE ENTER Enter PC phone up to 32 digits and press ENTER To erase WinLoad phone panel ID and PC password press the SLEEP key for 3 seconds 5 PANEL ID Enter 4 digit Panel ID 6 PC PASSWORD Enter 4 digit PC Password Step Action Details 1 INSTALLER CODE flash 2 3 1 4 PHONE ENTER Enter monitoring station p...

Page 43: ...ction Details 1 INSTALLER CODE flash Programmed zones are lit button or LED depending on keypad MAINTENANCE CODE may also be used 2 3 PGM NUMBER 2 digits 01 to 12 4 ENROLL OR ERASE PGM Hardwired PGM press ENTER To erase a PGM press the SLEEP key for 3 seconds 5 PGM TYPE 1 N A 5 Follow Bell 2 N A 6 Follow Arm 3 Follow Zone 7 Follow Stay arm 4 Follow Alarm 8 Follow Sleep arm 6 If PGM type is 3 or 4 ...

Page 44: ... Access Code Length 31 Account numbers 14 Ademco Contact ID 14 Ademco Express 14 Ademco Slow 14 Alarm Report Codes 25 Transmission Delay 15 Alarm Relay Connections 35 Alternate Dial 13 Answer WinLoad Software 30 Armed Report Delay 15 Arming Report Codes 24 Arming Disarming Options 12 ATZ 5 ATZ Connections 34 Audible trouble warning 12 Auto Test Report 15 Auto Test Report Time of Day 15 Auto Zone S...

Page 45: ...ager Reporting Delay 15 Message Repetition 15 Panic Options 12 Partition Timers 11 Partitioning 11 PCB Layout 37 38 PCS100 Connection settings 16 Programming 17 SMS Language 17 Personal Reporting Delay 15 Message Repetition 15 PGM Activation Deactivation Events 19 Connections 35 Delays Recognition 24 Event Description 20 Output Options 23 Quick Programming 41 Power Failure Report Delay 15 Pulse Ra...

Page 46: ...er 14 Special Keys 15 Test Mode 30 Test Report 30 Time and Date 39 Timers 12 Auto arm 12 Confidential mode 10 Partition 11 System 11 TLM Fail Delay 15 Options 13 Transformer Requirements 35 Trouble Display 30 U User Code Options 31 User Programming 31 V VDMP3 Arm Disarm Option 12 Calling the VDMP3 16 Maximum voice dialing attempts 16 Version Number Viewing 2 3 W Walk Test Mode 40 WARNINGS 0 WinLoa...

Page 47: ......

Page 48: ... outside Canada and the U S call 00 1 450 491 7444 Monday to Friday from 8 00 a m to 8 00 p m EST Please feel free to visit our website at www paradox com We hope this product performs to your complete satisfaction Should you have any questions or comments please visit www paradox com PARADOX COM Printed in Canada 11 2008 EX5 EP02 ...