High Security and Access System

EVO48 V1.20

EVO192 V1.20

Installation Guide

Includes Keypad Installation

Summary of Contents for Digiplex EVO48 V1.20

Page 1: ...rforms to your complete satisfaction Should you have any questions or comments please visit paradox com and send us your comments High Security and Access System EVO48 V1 20 EVO192 V1 20 Installation...

Page 2: ......

Page 3: ...rict Arming on Battery Failure 16 Restrict Arming on Bell or Auxiliary Failure 16 Restrict Arming on TLM Failure 16 Restrict Arming on Module Troubles 16 Timed Auto Arming 16 No Movement Auto Arming 1...

Page 4: ...odes 34 Installer Code 34 Access Code Length 34 System Master Code 34 Programming Access Codes 34 User Options 34 Partition Assignment 35 Access Control 35 Access Control System Features 36 Common Acc...

Page 5: ...tive triggering PGM1 can be used as a 2 wire smoke input 96 user codes 4 partitions 1024 events buffered Program remote controls using the master or installer codes Up to 96 remote controls with one M...

Page 6: ...6 on page 30 2 5 1 Battery Test The control panel conducts a dynamic battery test under load every 60 seconds If the battery is disconnected if its capacity is too low or if the battery voltage drops...

Page 7: ...ply and lead to complete system shutdown PLEASE NOTE When powering up the EVO control panel the panel will begin a module scan to verify if all the modules connected to the panel are operational The s...

Page 8: ...Modules APR ZX8 _______ X 30mA __________ mA Magellan Wireless Expansion Modules MG RTX3 _______ X 35mA __________ mA 4 PGM Expansion Modules APR3 PGM4 _______ X 150mA __________ mA Printer Modules A...

Page 9: ...terminal connections recognized by the Digiplex EVO system For UL listed installations use EOL resistor part 2011002000 Power required by devices connected to control panel s auxiliary output must no...

Page 10: ...ences or across separate buildings use shielded cables Within the Same Building Strip the outer jacket at one end of the shielded cable to expose the shield and connect the shield to the control panel...

Page 11: ...he control panel to transmit the Fire Loop Trouble report programmed in section 2906 To reset unlatch connect the smoke detector s negative to a PGM Then program the PGM with the Smoke Detector Power...

Page 12: ...ntrol panel will save the data and go to the next section or press the ENTER key to save the data and go to the next section Press the CLEAR key go to the preceding step or to erase the current data e...

Page 13: ...A Ademco express or Pager formats Key in desired 2 digit hex values from 00 to FF Ademco format Use section 4032 to program a set of default Ademco report codes from the Auto Report Code Programming o...

Page 14: ...ntry Delay Timers To program an Entry Delay Timer key in the desired 3 digit delay value 001 to 255 seconds into the corresponding section These are the same timers used for Stay Delay zones 4 4 3 Fol...

Page 15: ...steady or report only Fire alarms generate an intermittent signal see Figure 13 UL Warning For UL ULC installations a Fire Zone cannot be bypassed and its alarm type must be Pulsed audible Figure 13 B...

Page 16: ...ion detectors and door contacts Set the Input Speed 001 to 255 X 30ms default 600ms Option Feature Description 5 6 OFF OFF Steady Alarm sends the report code and activates the bell output ON OFF Pulse...

Page 17: ...rs enable option 7 in section 3033 For details on using EOL resistors refer to Addressable Zone Connections on page 5 and Double Zone Connections on page 6 4 9 Keypad Numbering SECTIONS 2801 TO 2832 K...

Page 18: ...button Template To select a button template as the default template enter 00 to 15 representing button templates in sections 2900 to 2915 2941 Assign Button Template To assign a button template to a...

Page 19: ...ility Key Event corresponding to the desired keyswitch see PGM Programming Table in the EVO Programming Guide Event Group 048 2 Enable option 4 in the section corresponding to the desired keyswitch 6...

Page 20: ...considers all open zones as temporarily bypassed except 24hr zones The control panel transmits the Auto Arming report code programmed in section 3910 The control panel will transmit the Late to Close...