background image

40 User’s Manual

Warranty

The Seller warrants its products to be free from defects in materials
and workmanship under normal use for a period of one year. Except
as specifically stated herein, express or implied warranties
whatsoever, statutory or otherwise, including without limitation, any
implied warranty of merchantability and fitness for a particular
purpose, are expressly excluded. Because Seller does not install or
connect the products and because the products may be used in
conjunction with products not manufactured by Seller. Seller cannot
guarantee the performance of the security system. Seller obligation
and liability under this warranty is expressly limited to repairing or
replacing, at the Seller’s option, any product not meeting the
specifications. In no event shall the Seller be liable to the buyer or
any other person for any loss or damages whether direct or indirect
or consequential or incidental, including without limitation, any
damages for lost profits stolen goods, or claims by any other party,
caused by defective goods or otherwise arising from the improper,
incorrect or otherwise faulty installation or use of the merchandise
sold.

Specifications may change without prior notice.
For the latest information on product approvals, such as UL and CE,
please visit our Web site at www.paradox.ca
Digiplex 848 and DigiplexNE are trademarks of Paradox Security
Systems

© 

2002 Paradox Security Systems

Summary of Contents for Digiplex DGP2-648

Page 1: ...48 Zone LED Keypad User Manual DGP2 648...

Page 2: ......

Page 3: ...icator Lights 5 PARTITIONED SYSTEM 7 Area Display 7 ZONES 8 Zone Display 8 ARMING 9 Exit Delay Timer 9 Regular Arming 9 Stay Arming 10 Instant Arming 10 Force Arming 11 One Touch Keys 12 Keyswitch Arm...

Page 4: ...S 29 Programmable Outputs PGMs 29 Panic Alarms 29 Programming Chime Zones 30 Programming the Time 32 QUICK FUNCTION KEYS 33 FIRE AND BURGLAR ALARMS 34 Standard Fire Zone 34 Delayed Fire Zone 34 Fire S...

Page 5: ...y to use Since you will communicate your instructions to the system through your keypad please read this manual carefully and have your installer explain basic system operation 1 1 LEGEND Indicates a...

Page 6: ...1 A2 A3 and A4 ON Area armed OFF Area disarmed FLASH Area in alarm Action Lights Access Stay Force Mem Trbl and Prg Lights will illuminate according to the status of the system Numerical Lights Zones...

Page 7: ...tent beep tones BEEP BEEP BEEP Rejection Beep When reverting to a previous status or when an operation is incorrectly entered your keypad will emit a continuous beep BEEEEEEEEP 2 2 KEYPAD INDICATOR LI...

Page 8: ...s feature your keypad will permit you to complete more than one action without having to reenter your User Access Code Press the Clear key to exit the User Menu 2 2 4 ILLUMINATION You can adjust the i...

Page 9: ...AREA DISPLAY The Area Status Display enables you to see the status of the individual areas within a partitioned system see section 3 0 Depending upon which system you have your installer can partition...

Page 10: ...e TRBL action light if any troubles are occurring The STAY action light if the area is Stay or Instant Armed The FORCE action light if the area is Force Armed The BYP action light if zones are bypasse...

Page 11: ...its and the keypad can be programmed to beep while the time elapses on the timer 5 2 REGULAR ARMING This method is used for everyday arming of the system All zones within the protected area must be cl...

Page 12: ...is similar to Stay Arming Instant Arming will partially arm your system to permit you to remain in the protected area but all zones including the entry exit points are changed to Instant Alarm Zones T...

Page 13: ...will remain unarmed will be ignored until you exit the area that it protects The system will then arm the motion detector How do I Instant Arm 1 Enter your Access Code Your keypad will emit a Confirma...

Page 14: ...se refer to their respective sections 5 7 KEYSWITCH ARMING Your installer can add a keyswitch to arm and disarm your system Your installer can program the keyswitch to arm in Regular Stay Force or Ins...

Page 15: ...ad will emit a Confirmation Beep and the ACCESS action light will flash 2 Press the 0 key Your keypad will emit a Confirmation Beep and the PRG action light and area light s will flash 3 Press the Mem...

Page 16: ...period of time Speak to your installer about this feature 5 9 BYPASS PROGRAMMING The installer can program certain zones with the bypass option This will enable you to program the system to bypass cer...

Page 17: ...l flash 3 Enter the two digit number s of the zone s you want to bypass and the corresponding number s will illuminate If a zone s number is illuminated and you reenter its number the zone will unbypa...

Page 18: ...uminate The BYP action light will also flash 3 Press the Mem key All zones numerical lights bypassed during the last time the system was armed will illuminate and will be bypassed 4 If you wish reente...

Page 19: ...am designated entry points such as the front door or the garage door with an entry delay This delay will allow you enough time to enter your code to disarm the system before the alarm is triggered 6 2...

Page 20: ...e in alarm will remain in the Alarm Memory until the next time that area is armed How do I disarm a system in alarm 1 Enter your Access Code 2 Call your security company quickly to advise them of the...

Page 21: ...aster Code cannot be less than 4 digits 7 1 SYSTEM MASTER CODE Default 1234 123456 The System Master Code will give you access to all the features as well as the ability to add modify or delete any Us...

Page 22: ...hich will allow you to control the access to your system Only the System Master Code and codes with the Master feature can program User Access Codes with their User Options and Area Assignment 4 Enter...

Page 23: ...flash for an unused code If the code is used PRG action light and the first number of the code will illuminate The ACCESS action and area light will turn off 5 Enter a User Code If you do not want to...

Page 24: ...ed will illuminate Press the U key and the numbers will illuminate one at a time as you press the key numerical light 10 represents zero Table 1 User Options Options on the User Access Codes that acti...

Page 25: ...ypass Feature OFF Bypass feature disabled ON default Bypass feature enabled Can deactivate zones using the bypass programming feature 5 Arm Only OFF default Arm only feature disabled ON Arm only enabl...

Page 26: ...ming the numerical LEDs 1 to 4 will illuminate and correspond to areas assigned to LEDs A1 to A4 respectively Press option ON OFF Option Description 8 Area Access OFF default User Access Code obeys th...

Page 27: ...7 4 ERASING ACCESS CODES To delete existing Access Codes press the Clear key in steps 5 6 and 7 in on page 21 Once the information is erased press the Enter key to save and exit 7 5 KEYPAD LOCK OUT If...

Page 28: ...h with a brief explanation Contact your security company in the event of an un listed trouble We strongly suggest that you inform your security company of the trouble and allow them to service your sy...

Page 29: ...output will shutdown until the troubled has been rectified Trouble 4 Bell Current Limit The bell of siren connected to the system has exceeded current limits The bell siren output will shutdown until...

Page 30: ...e and date have been reset to the default This is the only trouble that we recommend that you correct How do I set the time within the trouble menu 1 Press the 8 key 2 Enter the hour and minutes accor...

Page 31: ...hen you press a pre determined combination of number keys on your keypad The three Panic Alarms can be programmed to request help from the police a medical facility the fire department or anyone you w...

Page 32: ...m my keypad to beep every time a zone opens 1 Enter your Access Code Your keypad will emit a Confirmation Beep The ACCESS action light will flash 2 Press the 9 key to enter the Chiming Menu Your keypa...

Page 33: ...umerical light will illuminate The numerical light represents the first number of the previously set time numerical light 10 zero When the A2 and A3 area lights flash this means that no time value has...

Page 34: ...w do I program the time 1 Enter your Access Code 2 Press the TRBL key 3 Press the 8 key 4 Enter the hour and minutes according to the 24 hour clock i e 9AM is 09 00 and 9PM is 21 00 5 Enter the correc...

Page 35: ...ed will be able to access these functions How do I Access the Quick Function keys 1 Enter your System Master Code or Access Code with Master feature 2 Press the 0 key 3 Press one of the following for...

Page 36: ...installer 11 2 DELAYED FIRE ZONE During a delayed fire alarm the bell siren will emit an intermittent sound BEEP BEEP BEEP until silenced or reset If the zone is a delayed Fire Zone there is an automa...

Page 37: ...Digiplex 848 DigiplexNE LED Keypads 35n Figure 2 Delayed Fire Zone...

Page 38: ...side 3 Practice the escape plan frequently 4 Plan two ways to escape from every room if possible 5 Practice feeling the way out with eyes closed 6 Remind everyone never to stand up during a fire alway...

Page 39: ...tments the heating systems in single family homes are often not professionally maintained 4 Since fires produce smoke and deadly gases that can overcome occupants while they sleep smoke detectors shou...

Page 40: ...tails on the best way to test your particular system 12 2 FIRE ALARM TESTING Do NOT use an open flame or burning materials to test your fire detection devices Your installer will provide details on th...

Page 41: ...advise them that you are testing the system 2 Enter your Access Code 3 Press the 8 key The system will test all its connections and can send a report to your security company If the system detects a p...

Page 42: ...igation and liability under this warranty is expressly limited to repairing or replacing at the Seller s option any product not meeting the specifications In no event shall the Seller be liable to the...

Page 43: ......

Page 44: ...780 Industriel Blvd Saint Eustache Quebec J7R 5V3 CANADA Tel 450 491 7444 Fax 450 491 2313 www paradox ca PRINTED IN CANADA 11 2003 DGP2648 EU06...

Reviews: