SAFE
PROTECTOR
(950)
INSTRUCTIONS
English
Application
The Paradox Safe Protector is designed
for security applications on metallic
cabinets, cash-boxes, safe and metallic
doors. It can also be applied successfully
to protect concrete walls of bank
depositories and other premises requiring
high security protection level.
The Paradox Safe Protector is installed
directly on the protected surface and
reacts to the frequency spectrum of
vibrations caused by surface breaking,
cutting, and heavy knocking by grinders,
electric arc welders, and oxyacetylene
torches. It also reacts to knocking, filing
and drilling on the protected surface.
Since effective operation is contingent on
close contact between the safe protector
and the protected surface, this surface
must be well cleaned prior to installation.
The safe protector should then be tightly
attached to the safeguarded surface with
3 screws.
Installation
1. Remove center screw (
A
) on safe
protector.
2. Find a clean, dry, flat surface (
B
) on which
to mount the Paradox Safe Protector.
To reduce false alarms avoid
installation near:
• Electric motors,
transformers, fans, air
conditioners in close
proximity of the safe
protector
• Ultrasonic safe protectors
which may emit a signal
within the frequency range of
the safe protector
3. Install the 3 screws to mount the safe
protector ensuring that the screws are
driven in at a 120 degree angle.
4. Connect a 4 or 6-wire cable to the safe
protector and connect it as follows (see
Figure 2):
Tamper recognition:
1-2
Alarm contacts:
3-4
Power supply (+):
5
Power supply (-):
6
5. Set unit sensitivity according to
application:
100%: No jumper
70%:
Jumper on P and Q
50%:
Jumper on M and P
30%:
Jumper on N and Q
10%:
Jumper on M and N
6. Re-install the cover on the safe
protector.
7. Perform functional tests simulating a
burglary signal in the supervised area.
Example: lightly scratch the surface
around the safe protector with a
screwdriver or hit the surface near the
safe protector.
Specifications
•
Supply voltage: 10 - 16Vdc
•
Current consumption:
Standby: 16mA (+/- 10%)
•
Alarm: 12mA (+/- 10%)
•
Adjustable sensitivity:
100%: No
jumper
70%:
Jumper on P and Q
50%:
Jumper on M and P
30%:
Jumper on N and Q
10%:
Jumper on M and N
•
Diameter of protected surface: 2.50m
•
Alarm relay: 28V/150mA
•
Tamper output: Normally closed 24V/
0.2A
•
Temperature range: -20°C to +50°C
•
Maximum humidity: 95% at 25°C
•
Dimensions: 109 x 64 x 23mm
•
Weight: 260 grams
paradox.com
PRINTED IN CANADA - 02/2011 950-BI06
Figure 1
Figure 2
Warranty
For complete warranty information on this product please refer to the Limited Warranty Statement found on the
website www.paradox.com/terms. Your use of the Paradox product signifies your acceptance of all warranty terms
and conditions.
© 2011 Paradox Ltd. All rights reserved. Specifications may change without prior notice. One or more of the following
US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111, 5119069,
5077549 and RE39406. Canadian and international patents may also apply. Safe Protector is a trademark or
registered trademark of Paradox Ltd. or its affiliates in Canada, the United States and/or other countries.
A
closing cover screw
vis de fermeture du boitier
B
The surface must be well
cleaned and smooth.
La surface doit être propre
et lisse.
C
fixation screw
vis de fixation
D
wiring
câblage
E
cover
couvercle
F
anti-tamper switch
anti-sabotage
Never try to turn the large
screw-shaped cap on the safe
protector./ Ne jamais tenter de
dévisser la vis de fixation de
la chambre de détection.
A
B
C
D
E
F
G
back
dos
H
detection chamber
chambre de détection
G
H
Connection/Branchement
1-2
: tamper recognition/contact alarmes
sabotage
3-4
: alarm contacts/contact alarmes
détection
5
: power supply/alimentation (+)
6
: power supply/alimentation (-)
LED: alarm indication
DEL : indication d’alarme
Jumper/Cavalier