background image

I

MPORTANT INFORMATION

Limitation of liability
It is mandatory for the NEON panel to be installed in ac-

cordance with this manual, applicable codes, and the in-

structions of the Authority Having Jurisdiction. The manu-

facturer shall not under, any circumstances, be liable for 

any incidental or consequential damages arising from loss 

of property, or other damages, or losses owing to the fail-

ure of products beyond the cost of repair, or replacement 

of any defective products. The manufacturer reserves the 

right to make product improvements and change product 

specifications at any time.

The manufacturer assumes no responsibility for errors or 

omissions, whilst every precaution has been taken during 

the preparation of this manual to ensure the accuracy of its 

contents.

Warranty
PARADOX HELLAS warrants its products to be free from 

defect in materials and workmanship under normal use for 

a period of two (2) years (the “Warranty Period”) from the 

production-delivery date, identified by date code(s) indicat

-

ed on the products. Because PARADOX HELLAS does not 

install or connect the products and because the products 

may be used in conjunction with products not manufac-

tured by PARADOX HELLAS, PARADOX HELLAS cannot 

guarantee the performance of the fire alarm system and 

shall not be responsible in any way whatsoever for faulty 

installation or connection.

Declaration of Conformity

Fire  alarm  control  panel  NEON  is  certified  from  EVPU  (Noti

-

fied  body  No.  1293)  according  to  European  Regulation 

CPR 

305/2011

 with certification number Νο.

1293-CPR-0604

 of June 

27, 2018.

-Standards:

EN 54-2: 1997/A1: 2006/AC: 1999

EN 54-4: 1997/A2: 2006/AC: 1999

Certificates can be found online at phsvesis.com.

RoHS directive compliance

The EC RoHS guideline has been released in order to 

reduce the heavy metal load in electrical and electronic 

products caused by e.g. lead and mercury. All manu-

facturers are obligated to provide only RoHS-compliant 

products  to  the  European  market,  effective  from  July 

1st, 2006.

PARADOX HELLAS

 hereby states that the NEON 

panel  is  fully  compliant  with  RoHS  2002/95/EC  direc

-

tive.

Disposal of your old appliance

1.  When  this  crossed-out  wheeled  bin  symbol  is  at

-

tached to a product it means the product is covered by 

the European Directive 2002/96/EC.

2. All electrical and electronic products should be dis-

posed of separately from the municipal waste stream 

via designated collection facilities appointed by the gov-

ernment or the local authorities.

3. The correct disposal of your old appliance will help 

prevent potential negative consequences for the envi-

ronment and human health.
4. For more detailed information about disposal of your 

old  appliance,  please  contact  your  city  office,  waste 

disposal service or the shop where you purchased the 

product.

Summary of Contents for DEVELOPED Neon 2

Page 1: ...Installation and Operation Manual Conventional Fire Alarm Control Panel Version 1 Revision 4 ...

Page 2: ... be responsible in any way whatsoever for faulty installation or connection Declaration of Conformity Fire alarm control panel NEON is certified from EVPU Noti fied body No 1293 according to European Regulation CPR 305 2011 with certification number Νο 1293 CPR 0604 of June 27 2018 Standards EN 54 2 1997 A1 2006 AC 1999 EN 54 4 1997 A2 2006 AC 1999 Certificates can be found online at phsvesis com ...

Page 3: ...Level 2 Indication 9 5 3 14 General Fire Alarm Indication 9 5 3 15 Zone ALARM indications 9 5 3 16 General Fault indication General Fault 10 5 3 17 Zone Disablements Test Fault indications 10 6 Alarm Verification 10 6 1 System Overview Alarm Verification 10 6 2 System Operation Alarm Verification 10 6 3 Day Night hardware input 10 6 5 System Setup Zone assignment Intellizone 11 6 6 System Setup In...

Page 4: ...emote reset input 15 Zone inputs 16 Batteries Secondary standby power source See sec tion 9 2 17 JP204 NO NC dry contacts operated during reset 18 AUX R Auxiliary power output interrupted during re set 24 V DC 1 A max for devices that need resetable power This output is fused 19 AUX Auxiliary power output 24 V DC 1 A max This output is fused 20 BELL Bell class change operation input See sec tion 5...

Page 5: ...tion Terminal Mains Power Supply 230 V AC 50 60Hz 2 5A Fuse 1A 250V Slow blow Hardware Reset Button Fuse 5A 250V Slow blow Fuse 1 6A 250V Fast blow 1 2 Neon Panel Wiring diagram and information 4 7K Signaling device 24 V DC Active End Of Line Capacitor End Of Line Resistor Panic button Photoelectric detector Rate of Rise Heat detector 4 7K 22uF AEOL 1 End Of Line Device 2 Active End Of Line Device...

Page 6: ...Connect batteries Test for proper operation After a system power up the user must perform an A L 2 Reset to remove the System fault and enter normal operational mode This is by design 3 2 Installing the cabinet Cabinets can be surface or flush mounted See Figure 1 and Table 1 for framing and mounting dimensions To wall mount the cabinet 1 Position the cabinet on the finished wall surface 2 Fasten ...

Page 7: ... While key 4 is kept pressed the panel shows the configu ration related to the 4 Siren relay outputs Fault indicators FL1 FL8 Zones that will be de layed if triggered by an alarm are blinking Siren Indicators S1 to S4 Siren outputs that will be delayed are blinking Siren Indicator 2 S2 If allocated to Pre alarms is ON steady Key 6 Test On Normal press or while kept pressed all the visual indi cato...

Page 8: ... the 3 second activation the panel performs a zone reset useful for automatic detec tors Any zone in this state is considered disabled and is so in dicated If any zone is in test mode the TEST indicator is illuminated Key 7 EVACUATION Long Press This operation requires Access level 2 if SW C 8 is set see section 8 3 key 7 above Key 8 RESET panel Exit A L 2 Long Press The reset operation will Remov...

Page 9: ... 1 at least one zone is in testing mode steady on In access level 2 the system is in test selection zone mode blinking 5 3 8 Outputs Delay Indication The meaning of this indication is as below OFF No delays to outputs are active or programmed ON The system has programmed and active delays to outputs BLINKING The system has programmed delays to outputs but they are currently disabled with an Access...

Page 10: ...Alarm signal Only then will the General Alarm condition be activated To prevent the First Alarm signal from causing a General Alarm it must originate from an intellizone Please note that the terms Alarm Verification and intelli zone are treated as synonymous in the following sections 6 2 System Operation Alarm Verification Each zone may be programmed to be an Intellizone from microswitch SW B The ...

Page 11: ...outputs without delay called Im mediate Zones A group of outputs relays that will always activate without delay called Immediate Outputs A group of outputs relays that will activate with de lay if the Alarm is triggered by a Delayed zone called Delayed Outputs Additionally there is a predefined delay in access level 3 dip switches SW C 1 2 3 called Output Delay 7 2 System behavior The term Delayed...

Page 12: ... the pair are indicated in alarm 8 1 2 System setup Zone inputs To enable the cross zoning function place the appropriate micro switches to the ON position according to Table 6 Ex ample switching SWA 1 to ON will activate cross zoning on zones 1 and 2 The two zones 1st and 2nd should be connected to the detectors that are installed in the pro tected area A common practice is to install different t...

Page 13: ...current of the auxiliary out puts plus the siren outputs must not exceed 1 5 Amp The Alarm output also monitors the notification appliances wiring for open lines and short circuits The connection of a 4 7K Ohm EOL resistor is required as shown in below see section 1 2 4 7K 4 7K 4 7K 4 7K 4 7K 4 7K 4 7K 4 7K Signaling device 24V DC Panic button Photoelectric detector Rate of Rise Heat detector Figu...

Page 14: ...____ Zone 4 _______________________________________ Zone 5 _______________________________________ Zone 6 _______________________________________ Zone 7 _______________________________________ Zone 8 _______________________________________ Installed by Name Company Address Phone For service contact Company Address Phone Acceptance Inspection by Date DEVELOPED BY PARADOX HELLAS S A Korinthou 3 Meta...

Page 15: ...mounting extruding depth 25mm Weight without the batteries 2 800gr Appendix B Calculations Battery calculation worksheet Use this worksheet to determine the minimum capacity required for the panel s standby battery You can obtain operating current re quirements for notification appliances from their respective installation sheets Standby Current mA Alarm Current mA Base panel 1 Aux current Detecto...

Page 16: ...Document Part Number NEON PI01 CPR version 1 revision 4 12 2018 ...

Reviews: