Connect Griddle to Gas Source
HSL-32 Hibachi Griddle Operator Manual
When the griddle is not in use, completely turn off the gas supply at
the LP gas cylinder.
Never store the griddle indoors with the LP gas cylinder connected.
Always disconnect and remove the LP gas cylinder from the griddle
before storing the griddle indoors.
2.
Ensure all griddle control valves are in the OFF position
3.
Turn the LP cylinder OFF by turning the hand wheel clockwise until it stops
4.
Remove the safety cap from the LP cylinder valve (below left)
5.
Insert the regulator nipple into the LP cylinder valve – keep the regulator in line with the LP cylinder
valve to avoid cross-threading (below right)
Figure 22 LP Cylinder Connection
6.
Rotate the regulator coupler nut clockwise until you meet resistance, then tighten another 1/2 to
3/4 turn. Tighten by hand only – do not use any tools
7.
If the cylinder connection cannot be completed, disconnect the regulator and try again; if the
connection still cannot be made, do not use this regulator and obtain a replacement regulator
8.
To disconnect the LP gas tank, turn off the main cylinder valve; rotate the black coupling nut
counterclockwise until disengaged
Leak Test
Never use a lighted match or other open flame to check for leaks.
Do not smoke or allow other sources of ignition in the area while doing
a leak test.
Do not attempt to repair an LP cylinder valve if it is damaged. The
cylinder must be returned to a proper LP tank supplier and replaced.
Always conduct the leak test outdoors in a well-ventilated area.