GXL-45 Operator Manual
Troubleshooting
•
43
Figure 38 Adjust Air Gap
2.
Confirm the air shutter is set to the appropriate mark – N for natural gas, P for LP gas
3.
Make small changes to adjust the shutter position
a.
Loosen setscrew
b.
More open to allow more air to decrease the flame size
c.
Less open to allow less air to increase the flame size
d.
Tighten the setscrew
4.
Re-install the burner(s), test the flame, and adjust again as needed
5.
Repeat for all burners as needed
Confirm Gas Type
If the air mixers have been set and the grill flame is still not performing as expected, check to ensure the
primary gas orifice is the correct type as follows:
1.
On the top left corner of the grill’s back side is a small access panel
2.
Use a Phillips screwdriver to remove three of the screws; loosen one of the bottom screws but leave
it in place and let the panel swing down and out of the way
3.
Inspect the number stamped on the main orifice (circled above right); 1.1 indicates LPO gas, and 1.5
indicates natural gas