GSL-SB2B Double Side Burner Operator Manual
Connect Double Burner to Gas Source
•
25
Natural Gas
The burner unit must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure testing
of the gas supply piping system at test pressures equal to or less than
0.5 psi (3.5 kPa).
The burner unit must be isolated from the gas supply piping system
during any pressure testing of that system at test pressure in excess
of 0.5 psi (3.5 kPa).
Do not use any tape, pipe dope, or threading compound on any flare
fitting. Doing so may cause a clog in the regulator and prevent your
burner unit from safe and proper operation
To connect the burner unit to a natural gas source:
1.
Ensure all burner unit control valves are in the OFF position
2.
Connect a suitable natural gas flex connector to the burner unit gas inlet connection
Figure 17 Natural Gas Connection
Turn on the main gas supply and check all connections for leaks as described in the Leak Test procedure
below.
LP Gas
The consumer must provide a regulator to connect the burner unit to the LP gas cylinder. Ensure the
regulator is equipped with a hose long enough to reach from the burner unit’s gas intake fitting to the LP
cylinder. The regulator must use a 3/8” connector to attach to the burner unit (below right).