Parabeam 700-FSK Installation Manual Download Page 1

Parabeam

LONG RANGE ALERT SYSTEMS

®

INSTALLATION MANUAL

Paratronics Developments Ltd, Kapiti New Zealand

Phone/Fax: +64 4 297 2386 | Email: [email protected]

www.parabeam.co.nz

SITE CODE:

Summary of Contents for 700-FSK

Page 1: ...Parabeam LONG RANGE ALERT SYSTEMS INSTALLATION MANUAL Paratronics Developments Ltd Kapiti New Zealand Phone Fax 64 4 297 2386 Email sales parabeam co nz www parabeam co nz SITE CODE...

Page 2: ...e imagined as being similar to a laser The Base Receiver can support up to two Beam sets which can operate on different zones The Base Receiver has the ability to activate compatible outdoor security...

Page 3: ...set select two suitable mounting points for the Beam set and solar panels one on either side of the area being monitored The Beam set needs to be installed so that each Beam Unit directly faces the ot...

Page 4: ...solar panel wires as shown in DIAGRAM 5 DIAGRAM 5 Preparing Solar Panel Wire Feed a solar panel cable through the black cable gland on the underside of each Beam Unit Connect the black and red wires...

Page 5: ...leared for at least 8 seconds the Base Receiver will again show Enrolled and Operating Normally a solid green light For example a moving tree branch interrupting the beam every few seconds will stop t...

Page 6: ...e 2 beam is blocked Something is blocking the beam 3 short beeps spaced nine seconds apart Zone 1 light blinking amber continuous Zone 1 no connectiv ity not receiving a signal from the Zone 1 Beam se...

Page 7: ...e instructions beginning on Page 3 of this manual This Site Code is a unique code to every Parabeam 700 FSK Driveway Alert System The Site Code enables several neighbouring Parabeam systems to operate...

Page 8: ...nt angles Setting the Beam length to the minimum strength setting removing both jumpers will reduce this effect If you are testing two Beam sets indoors at the same time ensure each Beam set is at lea...

Page 9: ...for zone sharing or single EOL resistor per zone input WIRED FOR ZONE SHARING DIAGRAM 16 shows the Base Receiver being powered by the alarm panel configured with connections for zone sharing DIAGRAM 1...

Page 10: ...ed With An Alarm Panel Wird for Single EOL Resistor Per Zone Input CONTACT INFORMATION For enquires please contact Paratronics Developments Ltd NEW ZEALAND Free phone 0508 PARABEAM 0508 727 223 AUSTRA...

Page 11: ...ited to the warranty specified for the specific item These products include GSM Controller Modules IP Cameras hunting covert cameras fixed wireless termi nals and Pocket Beepers HOW TO MAKE A WARRANTY...

Reviews: