Accuracy of measurements (from version 3.6 on)
•
Measurement input PT1000 two-wire: error (FSR*) 0,06% typ.,
0,1% max.
•
Measurement input 20mA: error (FSR*) 0,08% typ., 0,4% max.
•
Measurement input 150mV: error (FSR*) 0,03% typ., 0,05% max.
In order to comply with the limit values a recalibration every 2 years is
recommended.
*FSR = full scale range
Variants/ measurement (W x H x D)/ weight
•
IP40 aluminum profile casing for indoor use or within a switching cabi-
net: 110 x 60 x 25mm / ca. 200g
•
IP65 polycarbonate for outdoor installation: 200 x 150 x 77mm / ca.
655g
•
Test box with transformer and connection technology
3.4.3
SOL.Connect Sensor Kits
A Sensor Kit comprises one irradiance sensor, sensor for module temperature
(SOL.Connect Sensor T) and ambient temperature. It is available in 2 vari-
ants:
The sensor module must only be operated in connection with sen-
sors of a sensor kit. For all other sensors the functionality is not
guaranteed.