background image

 

 

Page 1 

Operation Manual 

 

Tone Generator & Amplifier Probe 

 
 
 
 
 

 
 
 
 
 
 

 
 

 

 

 
Amplifier Probe 

 

Features 

  Designed to identify and trace wires without necessary damaging the 

insulation. 

  Works with any Tone Generator. 

  Volume control for sensitivity adjusting to suit working environment. 

  Recessed ON/OFF button switch to prevent battery drain while standby. 

  Power supply by 9V battery with an average operating life of 100 hours. 

  Audio earphone jack for operating in noisy environment such as server 

room,etc. 

  LED for illustration of signal strength of tone receiving. 

 
 

Figure 1 Amplifier Probe 

Figure 2  Tone Generator 

Audio jack 

Volume 
control 

ON/OFF button 

LED 

Black 

 

Red 

 

Modular plug 

 

LED 

3-position 
toggle 
switch 

 
 

Tone Generator & Amplifier Probe

 

must be installed 9V. battery before operation

 

IMPORTANT 

 
 

Do not connect Tone Generator unit to live AC power line (220/110 VAC) or  
DC power line which exceed 120 VDC. 

Summary of Contents for Metodo2

Page 1: ...ply by 9V battery with an average operating life of 100 hours Audio earphone jack for operating in noisy environment such as server room etc LED for illustration of signal strength of tone receiving Figure 1 Amplifier Probe Figure 2 Tone Generator Audio jack Volume control ON OFF button LED Black Red Modular plug LED 3 position toggle switch Tone Generator Amplifier Probe must be installed 9V batt...

Page 2: ...le solid tone can be done by slide switch on PCB inside Connection the tone generator to line pair has 2 methods OFTEN USE METHOD GROUNDED Connect red clip to a wire and connect black clip to ground or large metal part for example rack cabinet See figure 3 This method provide strongest tone and often use If connection point is RJ11 RJ45 jack please use a self made modular plug to copper adaptor Se...

Page 3: ...es in group also have tones It may needs to set volume to the level which cancel brightness of background noise or crosstalk from LED before tracing Setting done by pressing button on probe touch the tip to those wires which have background noise or crosstalk and adjust volume down slowly from position high to low until LED brightness cut off or very fade Then start tracing without adjusting volum...

Page 4: ...on butt set verify a continuity of the line is good All above line testing by tone generator of item B are also can be done by connecting with RJ11 modular plug instead of test clips REMARK COAX LINE CONNECTING 1 Connect red clip to outer shield of coax and black clip to ground or large metal part for grounded method tracing 2 Connect one clip to outer shield and the other clip to center conductor...