Page 1: ...Hydro Wizard ECM 42 Operating manual ...

Page 2: ... Director Matthias Kählig Pappelweg 4 D 30179 Hannover Telephone 49 0 5130 60 957 27 Fax 49 0 5130 60 957 26 Panta Rhei Galerie Langen Hop 5 30900 Wedemark Brelingen MAIL info panta rhei aquatics de WEB www panta rhei aquatics de Version 11053845 As of 21 09 2015 ...

Page 3: ...of application 6 5 General description 7 a Functional description 7 6 Commissioning 8 a Checks before commissioning 8 b Installation of the pump 8 c Operation of the control 13 7 Cleaning function 15 8 Assembly and disassembly 16 9 Maintenance and cleaning 17 a General cleaning work 17 10 Troubleshooting 18 11 Disposal and environmental protection 19 12 Warranty 20 a Extent of warranty 20 b Warran...

Page 4: ...ro Wizard compared to other products is that a laminar flow and not a turbulent flow is produced by the Hydro Wizard A turbulent flow is not good for the fish As a result of the exact calculation of all components in the flow simulation the Hydro Wizard is unrivalled until today within the area of efficiency and the environmentally friendly scope of services Before the first commissioning please r...

Page 5: ......

Page 6: ... a safety socket outlet with a mains voltage of 100 240 V 50 60 Hz fuse at least 10 A Only use in closed rooms for aquarist applications Only connect the device in aquaria garden ponds and in their protection zones to an electrical outlet with residual current device earth leakage circuit breaker with a rated current of not more than 30 mA an DIN VDE 0100 If you have any questions concerning this ...

Page 7: ...intended to be used by persons including children with reduced physical sensory or mental capabilities or a lack of experience and or knowledge unless these persons are supervised by a person responsible for their safety or they receive instructions by this person on how to use the device The operator is responsible for the compliance of local safety regulations Within the working area the user is...

Page 8: ...fore commissioning ensure by an expert that the required electrical protective measures are available Please read the instructions in the operating manual concerning the topic Maintenance and cleaning All measures beyond this opening the pump and the switchboards in particular are not permitted Always contact the manufacturer in the event of repair ...

Page 9: ...ot be flooded When working on the device remove the mains plug from the socket The minimum immersion depth depends on the set pumping capacity The maximum operating depth is limited by the cable length Before commissioning your new pump have an expert checked whether the Grounding protective multiple earthing and residual current operated protective circuit work properly following the latest safet...

Page 10: ...nets may cause crushing injuries on fingers and other extremities due to their enormous force Never take your hands ferrous materials or other magnets between the magnets Keep the magnets away from pacemakers As a result of the high magnetic force surrounding objects e g knives may be attracted in an uncontrolled manner Never put the holding magnet in direct contact with the magnets on the Hydro W...

Page 11: ...ient circulating of water is a basic function in this connection Dead zones can thus be avoided With the help of the optionally available USB interface wave simulations can be driven via a connected PC Thereby wave height and wave length can be adjusted This is used to simulate courses of rivers tides and breakers The Hydro Wizard is designed for use in freshwater and seawater ...

Page 12: ...onal description By rotation of the impeller an area of low pressure is generated which sucks in the medium from behind through the fins of the basket and past the flow conditioner ejects it again at the front 5 1 2 3 4 1 Magnet support 2 Motor 3 Basket 4 Impeller 5 Flow conditioner 6 Multi function button MFB 6 ...

Page 13: ...ithout finger protection Are there any objects in the drive that may block the impeller Are still people in the tank Make sure that the mains plug was disconnected before installing the drive in the tank b Installation of the pump 1 Installation step Attach the pump to the inside of the pane please exclusively on the intended points of attachment of the pump In order to do so use either the enclos...

Page 14: ...and may possibly damage the tank Furthermore the outer single magnets are not intended for use in water Water may penetrate which leads to the corrosion rusting of the magnets Appropriate mounting material can be purchased directly from Panta Rhei Information on this can be found on page 26 of this operating manual The dimensions can be found in the dimension drawing on page 24 The Hydro Wizard it...

Page 15: ...may be the result In order to avoid that increase the distance to the ground Objects sucked in may emerge from the flow conditioner at high speed and cause damage It must be ensured that the intake basket is not covered by plants and similar objects The cable must be protected against animals which are able to damage the cable It is advisable to remove from the inside algae and biofilms from the a...

Page 16: ...Hydro Wizard ECM 42 Operating manual 11 ...

Page 17: ...tly with a socket Then place the multi function button to the ON field of the control box Important note When switching on for the first time the speed of the drive should be increased slowly by turning the multi function slowly to the right and while doing so observing the flow effects in the tank Is something sucked in or are decorative items or plants blown away If this is the case choose a dif...

Page 18: ...he multi function button is kept on the control box magnetically It can be positioned on two positions on the housing Positon ON or position OFF Is the multi function button is on the position ON status indicator at the lower right lights up the flow velocity of the pump can be changed here by turning the button Here the speed is displayed at the lower left by LEDs see also table on page 14 Speed ...

Page 19: ...9 398 160 511 920 60 79 1 800 2 099 511 920 597 240 80 99 2 100 2 350 597 240 668 400 100 2 350 668 400 As standard the Hydro Wizard is after connecting to the power supply in the stop If the multi function button is removed from the control box the control box re tains the last setting In order to switch off the Hydro Wizard just switch the multi function button to OFF ...

Page 20: ...wo seconds in the opposite pumping direction The cleaning function is used e g to remove parts of aquatic plants that are entangled in the Hydro Wizard An individualisation of the break times is possible via an optionally available software and USB interface See Optional accessories page 26 Attention The cleaning function does not replace regular maintenance and cleaning ...

Page 21: ... can be pull out to the front after turning in clockwise direction In order to replace the impeller you require a Torx screwdriver T6 In order to do so hold the impeller with your hand and loosen the screw counter clockwise Tightening torque max 60 Ncm When carrying out assembly and disassembly always disconnect the mains plug in advance ...

Page 22: ...liquid Regulate the performance of the pump in such a way that a point flashes in green on the display Run the drive for one hour Replace the cleaning mixture by ten litres of clear water and run the motor again for one hour This measure should be carried out at least once a year for reasons of precaution Check the condition of the cables regularly They might be damaged by friction or animals a Ge...

Page 23: ... inserted Connect the motor to the control box After a power failure the speed is set to zero Up regulate the speed again Pump stops suddenly The impeller is blocked Disconnect the drive from the mains Remove the block Power failure Check the home fuse After a power failure the speed is set to zero Up regulate the speed again The motor does no longer generate a flow The inlet basket is contaminate...

Page 24: ...ting manual 19 11 Disposal and environmental protection The device must not be added to the normal household waste but must be disposed of professionally For this purpose please contact your local disposer DIRECTIVE 2002 96 EC ...

Page 25: ...anty entitlement c Warranty exclusions The following are not covered by this warranty use for other than the intended purpose accidents or changes to the hardware or software unauthorized modifications an unsuitable physical or operational environment which does not meet the product specifications inexpert maintenance or defects caused by a product for which Panta Rhei GmbH is not responsible Ther...

Page 26: ...Hydro Wizard ECM 42 Operating manual 21 obliged to replace products which are not covered by this limited warranty ...

Page 27: ...Operating manual Hydro Wizard ECM 42 22 13 Technical data a Pump characteristic curve ...

Page 28: ... 240 V 50 60Hz max power consumption 33 W min speed 400 rpm max speed 2 350 rpm max flow rate 11 280 l h max medium velocity 3 3 m s Axial thrust 5 5 N max operating depth conditioned by cable length Weight motor basket 408 g Total weight 1 026 g max medium temperature 35 C max ambient temperature 40 C ...

Page 29: ...Operating manual Hydro Wizard ECM 42 24 c Dimensions All dimensions are in mm ...

Page 30: ...Hydro Wizard ECM 42 Operating manual 25 d Connecting dimensions The bore holes in the rear side of the Hydro Wizard must not be covered ...

Page 31: ...pport Order no 428229 Mounting Adapter Order no 11054006 Single magnet Order no 428230 Sponge filter attachment Order no 11053026b USB adapter set Order no 11054197 For further information please contact our field workers or get yourself informed at http shop panta rhei aquatics com ...

Page 32: ...erating manual 27 15 Spare parts You receive all spare parts for the Hydro Wizard directly at Panta Rhei For further information please contact our field workers or get yourself informed at http shop panta rhei aquatics com ...

Page 33: ...Operating manual Hydro Wizard ECM 42 28 ...

Page 34: ...Hydro Wizard ECM 42 Operating manual 29 ...

Page 35: ...Operating manual Hydro Wizard ECM 42 30 ...

Page 36: ...Hydro Wizard ECM 42 A product of www panta rhei aquatics de ...