BA_PH_BSB-400-900_EN_44-21.docx
28
8.1.2.1
3.0 - 7.5 kW Models with Push-Switch Unit (Option)
Figure 18: Push-switch unit (3.0 - 3.5 kW)
•
Check saw blade tension (tighten if necessary).
•
Make sure that there are no objects on the machine,
the doors are closed and the safety switches (refer to
section
9.2) are locked.
•
Make sure that the brake release switch (
3
) is turned
to the left position (
“
inactive
”
).
•
Turn the main switch
on (position ”
I
”)
.
Remark:
The main switch is in the control cabinet.
Switching ON:
•
Press switch (
1
) and wait until the bandsaw has
reached its full speed.
Switching OFF:
•
Press switch (
2
)
→
Machine is braked.
•
To disconnect the machine from the power supply,
turn off the main switch (position
“
”
).
Release the brake:
•
Turn main switch (
1
) to position
“
I
”
.
•
Turn brake release switch (
3
) to the right (
“
active
”
")
→
Brake releases / control lamp (
3
) lights up.
8.1.3
Switch on Machines with Electric Brake
8.1.3.1
1.1 - 1.,5 kW Models with Push-Button Unit (Option)
Figure 19: Push-button unit (1.1 - 1.5 kW)
•
Check saw blade tension (tighten if necessary).
•
Make sure that there are no objects on the machine,
the doors are closed and the safety switches (refer to
section
9.2) are locked.
Switching ON:
•
Press button (
1
) and wait until the bandsaw has
reached its full speed.
Switching OFF:
•
Press button (
2
)
→
Machine is braked.
8.1.3.2
1.5
–
2.2 kW Models with Push-Switch Unit (Option)
Figure 20: Push-switch unit (1.5 - 2.2 kW)
•
Check saw blade tension (tighten if necessary).
•
Make sure that there are no objects on the machine,
the doors are closed and the safety switches (refer to
section
9.2) are locked.
•
Make sure that the
“
Ready
”
control lamp (4) lights
(doors closed / brake ok / emergency stop unlocked).
Switching ON:
•
Press switch (
1
) and wait until the bandsaw has
reached its full speed.
Switching OFF:
•
Press switch (
2
)
→
Machine is braked.
1
3
2
4
1
2
1
2
4