12D: Media Detect Error Troubleshooting
Error Location Indicator and State Potential Problem
Solution
Media Detect Error LED
On (steady)
Incompatible Media.
Use appropriate Panduit label media
Media installed incorrectly;
Label facing up.
Remove spool from unwind spindle,
flip the spool over, and re-install the
media.
Media Detection system is
obstructed.
Ensure Media Detect system camera
is unobstructed. Power cycle unit.
System does not operate, and
Media Detect Error LED is on.
Contact Panduit Service Center.
Media Detect Error LED
On (Flashing)
Media Detection Malfunction;
50 consecutive cycles without
Panduit media recognition
Power cycle unit. If this persist,
Contact Panduit Service Center.
12E: Media Error Troubleshooting
Error Location Indicator and State Potential Problem
Solution
Media Error LED
On (steady)
Incorrect Media selected or
loaded in the applicator.
Replace or select correct media with
selector. See figure 14C.
12F: Non- Indicated Errors/Failures Troubleshooting
Problem: Incomplete wrap/installation. Label does not adhere to cable during wrap process
Solution: Check for Label/Cable contamination
Problem: Incomplete wrap/installation. Label does not adhere to cable during wrap process
Solution: Use consistent application pressure between cable and label on both cable guides
Problem: Incomplete wrap/installation. Loose or telescoping wrap. Label does not adhere to
cable during wrap process.
Solution: Use wire straightener remove wire set prior to label application
Problem: Label stubs preventing it from fully feeding.