OptiCam 2 FS133 Termination Tool User Manual
-
28
-
Tool Care and Maintenance
1. The LC connector port and data port protective dust caps must be installed when the
tool is not in use to prevent contamination.
2. The camera aperture should be cleaned periodically with a soft, lint free cloth or with
isopropyl alcohol to remove dust and debris which may interfere with proper camera
operation. Avoid any scratches on the surface. The LC connector port can be cleaned
with clean dry air. Do not use alcohol.
3. The dust caps for both the LC connector (tool end) and the Ferrule Adapter (field con-
nector end) must be installed when the cord is not in use. Do not coil the cable to less
than one-inch diameter at any time to avoid damaging the fiber.
4. The fiber tip of the launch cords should be cleaned every 50 connector terminations. To clean, retract the boot to expose
the cable crimp sleeve. Remove the Ferrule Adapter by holding the crimp sleeve and unthreading from the Ferrule
Adapter Assembly to expose the white ceramic split sleeve.