![Panduit OptiCam 2 FS133 User Manual Download Page 25](http://html.mh-extra.com/html/panduit/opticam-2-fs133/opticam-2-fs133_user-manual_751661025.webp)
OptiCam 2 FS133 Termination Tool User Manual
-
25
-
Assemble Connector and Boot
LC Connector and Boot
1. Grip the boot by the large end and push the boot forward onto the grooved area of the backbone until it is against the
flange. The insertion mark should be at the end of backbone.
2. Clean the ferrule end face with an alcohol soaked wipe and then a dry wipe. Place the dust cap over the ferrule end.
3. (
Optional
) With a connector held as shown (latch on top, ferrule facing away), insert the connector into one side of the
duplex clip as shown (clip held with the “A->B” polarity marking upright and facing forward). The upper tab of the clip
should slide into the pocket underneath the latch of the connector, and the lower tab should slide under the connector
housing and “snap”, locking it into place.
Repeat this procedure for the other connector, completing the duplexing step.
Note
: When making cable assemblies, be sure to follow the correct “A->B” polarity cross-over
between connectors.