CHANGEOVER KITS:
KMTRTH
Changeover kit allows for installation of heavy (H) cross-section MRT and MRS style ties
in MTRTLS tool. Kit comes complete with one setshear finger (H), one anvil (H), three
screws, thread-lock tube and installation instructions.
KMTRTLS
Changeover kit allows for installation of standard (S) and light-heavy (LH) cross-section
MRT and MRS style ties in MTRTH tool. Kit comes complete with one setshear finger
(LS), two anvils (LH and S), three screws, thread-lock tube and installation instructions.
SAFETY PRACTICES
ALWAYS wear safety glasses when using this tool.
DO NOT place fingers near cutting blade during tool actuation.
Fingers may be pinched or injured by cutter blade.
DO NOT use tool on live electrical sources.
TO REPLACE ANVIL
Remove two screws holding Anvil onto the tool. A 3/32” Allen Wrench will be required. The screws may be very
tight as they have been installed with Loctite
®
. Once the screws are removed, slide the Anvil towards the front of
the tool and downward away from the tool. Set aside old Anvil.
**
Place new Anvil onto bottom of the tool. The
Anvil must straddle the two plates and have the slots toward the rear. When the Anvil is slid backwards, the slots
must engage the pins. If done correctly, the hole on each side of the Anvil will align with a tapped mounting hole
below. Replace the screws applying a drop of Loctite
®
to each screw. See pictures below.
** IF SETSHEAR FINGER IS TO BE REPLACED AS WELL, NOW IS THE TIME TO REPLACE PER
THE INSTRUCTIONS BELOW.
TO REPLACE SETSHEAR FINGER
Remove a single screw holding the Setshear Finger up onto the Sliding Detent Assembly. Use a 1/16” Allen
Wrench to remove the screw. The screw may be tight as it has been installed with Loctite
®
. Once the screw is
removed, slide the Setshear Finger toward the front of the tool. This should disengage it from the Sliding Detent
Assembly. Pull the Finger down out of the bottom of the tool. Installation is the reverse of these steps. When
replacing the Setshear Finger, the notch on the flat surface of the finger must engage the retaining tab on the
Sliding Detent Assembly. See pictures below.
WHEN COMPLETE, THE LOCATING SET SCREW ON THE FRONT OF THE TOOL WILL NEED TO
BE ADJUSTED PRIOR TO TOOL USE.
®