TM
Quick Set-up For CT-1000 Ferrule Crimp Tool
1. Cut Wire:
Insert wire into cutting guide and
close handles to cut wire.
2. Strip Wire:
Adjust orange wire stop to strip
length specified on the ferrule-
package label you are using. See
sample of package label below.
Insert wire until it hits stop and
close handles to strip wire.
Release handles and remove
stripped wire.
FSD80-8-DSL6
QTY. 500
FERRULE - STRIP
INSULATION (BLUE)
WIRE SIZE: 14 AWG (2.50 mm
2
)
FOR STR CU WIRE
MAX WIRE INSUL. DIA. 0.16" (4.0 mm
2
)
STRIP LENGTH 13/32" (10 mm)
Adjusting Strip Blade Depth
Adjustment screw should be used to
set strip blade depth. If insulation is
not being stripped turn adjustment
screw clockwise ¼ turn increments
until the desired wire strip is achieved.
If blade is cutting into insulation
too deep turn adjustment screw
counterclockwise ¼ turn increments
until the desired wire strip is achieved.
3. Adjust Crimp Force Setting:
FSD80-8-DSL6
QTY. 500
FERRULE - STRIP
INSULATION (BLUE)
WIRE SIZE: 14 AWG (2.50 mm
2
)
FOR STR CU WIRE
MAX WIRE INSUL. DIA. 0.16" (4.0 mm
2
)
STRIP LENGTH 13/32" (10 mm)
CRIMP TOOL: CT-1000, SETTING: 2.5
Open tool door as shown above
and adjust crimp force setting.
With door open, make dial and
slide adjustments to match specific
setting noted on package label.
Press in and rotate adjustment
dial, until desired die setting is
reached. Adjustment dial will
automatically click into place when
setting is reached. Adjust slide
control on cover so that the two
settings match. These two settings
must match to crimp correctly.
13/32
Tool Overview
PANDUIT continuously molded ferrules
and crimping tools deliver speed and
reliability for medium volume terminations.
The CT-1000 is a multi-use .54 lbs. controlled cycle
tool that crimps ferrules, and cuts and strips wire.
• Innovative rapid load design significantly reduces installation time
• Adjustable die setting allows termination of all continuously molded
strip-fed ferrules
• Designed for use with continuously molded ferrules in strips of 50
Note: Tool intended for use with soft coated, multi-stranded copper
wire and strip ferrules with polypropylene insulating collars
from 0.5 - 2.5 mm
2
.