AT-HDR-CAT-2
41
Configuration and Management Interfaces
RS-232 Parameter Setting
Click each of these drop-down boxes to select the desired baud rate, data bits, parity bit, and stop bit for the
MASTER RS-232 / IR
port.
Setting
Description
Baud rate
Sets the baud rate. The following options are available: 2400, 9600, 19200, 38400,
56000, 57600, 115200.
Data bit
Sets the number of data bits used to represent each character of data. The following
options are available: 7 or 8.
Parity
Sets the parity bit, which can be included with each character to detect errors during
the transmission of data. The following options are available: None, Odd, or Even.
Stop bit
Sets the stop bit. Stop bits are sent at the end of each character, allowing the client to
detect the end of a character stream. The following options are available: 1 or 2.
RS-232 page
RS-232