AT-DISP-CTRL
29
Configuration and Management Interfaces
CEC Command
Click the
ON
button to test sending the power-on command to the display device. Click the
OFF
button to toggle
the power state to off. Click the
+
,
-
, and
MUTE
to increase, decrease, or mute the audio output, respectively.
Display Auto Power
Set this toggle to
ENABLED
to allow the AT-DISP-CTRL to send the power-on command to the display when an A/V
signal is detected. When the AV signal is no longer present, the AT-DISP-CTRL will send the power-off command to
the display. If this feature is not desired, then set to
DISABLED
. This feature is enabled by default.
Auto power off timer
Sets the time interval before the command to power-off the display is sent, when an A/V signal is no longer present.
The default value is 15 seconds. Available values are 15 seconds to 1 hour.
Lamp cool down timer
Sets the projector lamp cool-down timer, in seconds. This value specifies the time interval that must elapse, after the
display control “off” command is sent, before the display “power on” command can be sent. This feature is used to
prevent the projector from missing a “power on” command while the lamps are cooling. Available values are 10 to
300 seconds. The default setting is 10 seconds.
Display Warm-Up Timer
Sets the time between when the projector lamp has been turned on to when it can receive new commands.
Click this drop-down list to select the display warm-up time interval. Available values are 10 seconds to 300
seconds. The default value is 10 seconds.
Control Type
Click this drop-down to select the control type. Available settings are
CEC
,
IP
,
RS-232
, and
IR Remote
.
Display Page
This page provides controls for CEC, device timers, and configuration for controlling external devices.