69 av 82
OPERATION AND MAINTENANCE MANUAL I ENG_OMM_CD200IQ_P03 I 2023-03-16
@Pandrol 2023
11.3. Maintenance schedule
Item
Action
Frequence
Before every
use
Once per
week or
every 40 h
Once per
year or
every 500 h
Hydraulic fluid
Check oil level with oil dipstick**
X
Hydraulic fluid
Replacement***
X
Hydraulic return filter Replace filter
X
Breathing filter tank
Replace filter
X
Complete machine
Check for leakage
X
Screws an nuts
Check and tighten if necessary
X
Lubrication Fastclip
work head
Lubricate with SKF LEGP 2 or similar
X
Slide plates on trolley Clean and lubricate with oil*
X
Screws
Lubricate with oil*
X
Engine
See Honda instruction manual
X
X
X
Decals and signs
Replace worn and missing decals and signs
X
Cleaning
Wash with warm water and clean with non
agressive solvents. Lubricate when the
machine is dry.
X
*) CRC 5-56, WD-40 or similar
**) Wait at least one hour before checking oil level.
***) Recommended hydraulic fluid:
At suurounding temperatures below 25°C, hydraulic fluid with viscosity class 46 is recommended. At surrounding
above 25°C, hydraulic fluid with vicosity class 68 is recommended.
It is important to follow these service intervals in order to guarantee safety.
Summary of Contents for CD200 IQ
Page 2: ...2 av 82 OPERATION AND MAINTENANCE MANUAL I ENG_OMM_CD200IQ_P03 I 2023 03 16 Pandrol 2023...
Page 53: ...53 av 82 OPERATION AND MAINTENANCE MANUAL I ENG_OMM_CD200IQ_P03 I 2023 03 16 Pandrol 2023...
Page 80: ...80 av 82 OPERATION AND MAINTENANCE MANUAL I ENG_OMM_CD200IQ_P03 I 2023 03 16 Pandrol 2023...
Page 81: ...81 av 82 OPERATION AND MAINTENANCE MANUAL I ENG_OMM_CD200IQ_P03 I 2023 03 16 Pandrol 2023...