EN
- 27 -
6. IMPORTANT: DETAILS TO BE TAKEN INTO ACCOUNT.
WARNING: Fluorescent strips, LEDs or strips of LEDs must be changed by an official
Pando technical service, as it involves handling internal electrical parts and the user is
not authorised to tamper with these.
a) Make sure the device is disconnected from the electrical power supply.
b) Remove the steel panel by unscrewing the screws holding it in place. Replace the fluorescent strip
or the strip of LEDs with a new one of the same model as the original (3.5W, 7W, 14W, 21W or 28W
depending on the model).
c) Reconnect the appliance to the mains power supply.
RECOMMENDED COOKING AREAS AND INSTALLATION GUIDELINES FOR BEST RESULTS WITH
CERTAIN SPECIAL MODELS:
DECORATIVE AND ISLAND HOODS:
• P-496: Only suitable for compact ceramic cooktops- 24 or 28 in width.
• P-497/ 36”: Only suitable for compact ceramic cooktops - 24 or 28 in width.
• P-497/ 48”: Only suitable for compact ceramic cooktops - up to 36 in width.
• P-797: Only suitable for compact ceramic cooktops - up to 13” deep.
• P-803: Only suitable for compact ceramic cooktops - 24 or 28 in width.
• I-402/ 36”: Only suitable for compact burners 24 or 28 in width.
• I-402/ 48”: Only suitable for compact burners up to 36 in width.
• I-496: Only suitable for compact burners 24 or 28 in width.
• I-497/ 36”: Only suitable for compact burners 24 or 28 in width.
• I-497/ 48”: Only suitable for compact burners up to 36 in width.
• I-803/ 40”: Only suitable for compact burners up to 36 in width.
• I-803/ 48”: Only suitable for compact burners 24 in width + modular up to 16 in width.
• I-960: Only suitable for compact burners 36 in width X 38 in deep.
WORKTOP HOODS: - NOT UL APPROVED AS OF 5/2013:
• E-300-310-320/ 36”: Only suitable for compact ceramic cooktops - 32 in width X 15” deep.
• E-300-310-320/ 48”: Only suitable for compact - ceramic cooktops - 36 in width X 14” deep.
• E-500/ 36”: Only suitable for compact ceramic cooktops - 32 in width X 15” deep.
CEILING HOODS:
• Access must be provided for at the side of the hood where the flue is to be connected before closing up
the false ceiling.
• The ceiling on which the hood is mounted must be completely smooth, with no unevenness or
difference in level of any kind.
• For these models to work properly, ventilation grilles must be fitted towards the bottom of one wall in
the room in order to let enough air in constantly for the power rating chosen.
• The maximum distance from FLOOR to FALSE CEILING must not be more than 2.50m.
FLUORESCENT STRIP OR STRIP OF LED
(To be carried out by qualified people and Pando technical support service only).