Warnings & Cautions

SYMBOL

MEANING

Risk of electric shock / risk of fire

Do not open. To reduce the risk of electric shock, do not remove cover (or back). No user serviceable parts 
inside. Refer servicing to qualified service personnel.

Burning Injuries 

Be aware of high case temperatures of 60-85°C during and after use of Sonara. Don’t touch the metal cases, 
frames, or LEDs to avoid burning injuries.

Flammable Materials 

Keep flammable materials away from the installation. The installation should be such that the amount of air flow 
required for safe operation of the equipment is not compromised. Proper ventilation must be provided.

ESD and LEDs 

LED components used in Sonara are sensitive to electro-static discharge (ESD). To prevent the possibility of 
destroying LED components do not touch during operation or when SONARA is switched off.

Light output 

Due to high light-output intensity do not look directly into the bare LED array. Use diffusers when exposing the 
light to human eyes.

Disconnect Device 

When the appliance inlets of any individual SONARAs are not accessible, the socket outlets supplying the 
rack shall be installed near the equipment and be easily accessible, or a readily accessible general disconnect 
device shall be incorporated in the fixed wiring. Disconnect device should state 3mm separation in both poles 
and should include reference to national wiring rules.

This equipment MUST be earthed 

In order to protect against risk of electric shock, the installation should be properly grounded. Defeating the 
purpose of the grounding type plug will expose you to the risk of electric shock.

Mains cords 

Use only a Neutrik PowerCon TrueOne NAC3FX-W-TOP Connector. The user is responsible for ensuring power 
cables are of adequate condition for each application. If the power cords are damaged, replace them only with 
new ones. Never try to repair a power cord.

Environmental: Disposal of old electrical & electronic equipment 

This symbol on the product or on its packaging indicates that this product shall not be treated as household 
waste.

LATEST VERSION AS OF JULY 2021

PANALUX SONARA 4:4 USER MANUAL

36

Summary of Contents for PANALUX SONARA 4:4

Page 1: ...The next generation enhanced variable white LED soft light S O N A R A 4 4 LATEST VERSION AS OF JULY 2021 User manual of SONARA 2021 Panalux Ltd All Rights Reserved...

Page 2: ...The next generation enhanced variable white LED soft light S O N A R A 4 4 LATEST VERSION AS OF JULY 2021 User manual of SONARA 2021 Panalux Ltd All Rights Reserved...

Page 3: ...Spare Parts Accessories 08 Appendix Gel Library Source Emulation List Overall Dimensions Rigging Centres 01 Important Information Warnings Safety Information Changes Measuring Correlated Colour Tempe...

Page 4: ...IMPORTANT INFORMATION WARNINGS 01...

Page 5: ...o measure the light output red green and blue As such a narrow band or discontinuous spectrum light source may not read correctly Colour meters such as the Sekonic C800 Spectromaster or UPR Tech MK 35...

Page 6: ...gsten lights 0 10 With multi colour LED fixtures in particular older Stage and Architectural LED fixtures where compatibility with film and digital cameras wasn t a consideration in their design indiv...

Page 7: ...INTRODUCTION 02...

Page 8: ...etween nodes lighting fixtures and a lighting desk typically on a private local network such as Ethernet Art Net can address over 30 000 universes Art Net designed by and copyright Artistic Licence Ho...

Page 9: ...USER INSTRUCTIONS 03...

Page 10: ...g quick triggers 4 in each corner and 2 on the outer edge of the back roughly aligned with the centre line and yoke mounting position 5 SONARA weighs 44kg excluding accessories and 38kg excluding yoke...

Page 11: ...hes a maximum surface temperature of 85 C Please ensure contact on the surface by persons or materials is avoided when the fixture is operating 6 Do not operate SONARA if there are any signs of physic...

Page 12: ...nging fails 2 The safety cable slot as shown on page 11 MUST be used to attach a safety cable 3 Ensure safety cables are capable of supporting the combined load of the SONARA and accessories Note SONA...

Page 13: ...FIXTURE OVERVIEW 04...

Page 14: ...hrough 5 pin DMX connector or via wireless DMX The SONARA user interface and wired remote have been designed to provide a clear and simple display of essential information The controller features 1 ro...

Page 15: ...of the controller and the other Lemo connector is inside the controller holding trough The controller features magnets and a lanyard to hang on a stand lock off There is a safety for the controller on...

Page 16: ...ARA Mounting Components Spigot Locking Handle Corner M12 Mounting Points Mounting Point Fitted With M12 Eyebolt Centre M12 Mounting Points LATEST VERSION AS OF JULY 2021 PANALUX SONARA 4 4 USER MANUAL...

Page 17: ...MX signals The DMX wiring is as follows Pin 1 Ground Pin 2 Data Pin 3 Data Pin 4 Spare Pin 5 Spare Please note SONARA is self terminating and does not require external DMX termination when used in a c...

Page 18: ...OPERATION 05...

Page 19: ...Art Net LOCKED when local control is locked DEMO when fixture is cycling through a demo In white mode shown above the display will always show Dim Position percentage CCT Green Magenta Bias Factory R...

Page 20: ...r it scrolls through the CCT range or gel list for example When controlling the dimming for instance this allows ultra fine control down to 0 1 steps Selector Buttons 3 selector buttons allow the user...

Page 21: ...t button touch will display the saved settings and the bar will turn red without changing the light output A second touch will change the output The scene memory can be overwritten Restoring to factor...

Page 22: ...me and number Full gel list in the Appendix pp 39 41 In this screen the live highlighted bottom button NAME in the top left example image allows toggling of LIVE ON and LIVE OFF In LIVE OFF mode you c...

Page 23: ...chart If the chosen colour point is out of gamut SONARA won t produce any output until the coordinates are adjusted to bring it within the achievable gamut The light will switch off during adjustment...

Page 24: ...CONTROL FEATURES OPTIONS 06...

Page 25: ...uilt in dimming curves CONTROL FEATURES OPTIONS Curve Characteristics Linear Default In linear mode 50 equates to half the output or 1 stop down 25 is quarter output or 2 stops down Square Law A squar...

Page 26: ...etric output changes at different CCTs In a studio environment where multiple changes are made to CCT it is often advantageous that the photometric output remains constant This is achieved in FLAT mod...

Page 27: ...inates which would be shown in a red font on the display In CCT HSI ALB or GEL mode if the colour is unachievable due to the chosen gamut the colour produced will be desaturated into the selected whit...

Page 28: ...tions from any This allows a DOP or gaffer to ride the dimmer when the talent is moving to a cue or during setup to make changes whilst talking to the board operator who may be backstage External Igno...

Page 29: ...L GEL P7 Gel Hue 24 bit BCD DIM CCT Gn GEL 000 GEL 00 GEL 0 HUE SAT P8 Gel Hue 16 bit DIM DIM CCT CCT Gn GEL GEL HUE HUE SAT SAT P9 ALB 8 bit DIM AMBER LIME BLUE P10 ALB 16 bit DIM DIM AMBER AMBER LIM...

Page 30: ...toring 2 RDM Protocol Version Monitoring 3 Device Model Description Fixed 4 Manufacturer Label Fixed 5 Software Version Fixed 6 Serial Number Fixed 7 DMX Footprint Monitoring 8 DMX Personality Descrip...

Page 31: ...perature in degrees Celsius 8 Temperature Array temperature in degrees Celsius 9 Temperature Array temperature in degrees Celsius 10 Temperature Array temperature in degrees Celsius 11 Temperature Arr...

Page 32: ...PRIMARY CLONE MODE STANDARD PIXILATION SFX ATTRACT CONTROL CURVES LINEAR SQUARE LAW S CURVE TUNGSTEN EMULATE OUTPUT BOOST FLAT GAMUT PX VARI WHITE REC 2020 REC 709 DCI P3 ESTA 1 54 CAMERA LUTS CONTRO...

Page 33: ...GENERAL 07...

Page 34: ...at the keyway aligns Two or more fixtures on the same address are behaving differently on dimming or CCT Ensure that all fixtures are set in the same option for personality dimming curve and FLAT BOOS...

Page 35: ...d below were taken with a SONARA at 3200K as above Sonara Luminous Intensity Height m Lux lx at Spread m Centre 1 2 2 4 3 7 4 9 6 1 7 3 8 5 9 8 11 0 12 2 3 2197 1859 1639 1420 1082 845 625 473 355 287...

Page 36: ...the light to human eyes Disconnect Device When the appliance inlets of any individual SONARAs are not accessible the socket outlets supplying the rack shall be installed near the equipment and be easi...

Page 37: ...ller extension cable pouch 124 8684 Aerial VIKLIA7 Power cord YJNBQAJ Soft box YIN9PAR Soft box bag JIN9RAR Full Grid Cloth JIN9SAR Half Grid Cloth JIN9TAR Quarter Grid Cloth JIN9QAR Magic Cloth GJNBP...

Page 38: ...APPENDIX 08...

Page 39: ...reen 89 Moss Green 90 Dark Yellow Green 101 Yellow 102 Light Amber 103 Straw 104 Deep Amber 105 Orange 106 Primary Red 107 Light Rose 108 English Rose 109 Light Salmon 110 Middle Rose 111 Dark Pink 11...

Page 40: ...d 165 Daylight Blue 169 Lilac Tint 170 Deep Lavender 172 Lagoon Blue 174 Dark Steel Blue 176 Loving Amber 179 Chrome Orange 180 Dark Lavender 181 Congo Blue 182 Light Red 183 Moonlight Blue 184 Cosmet...

Page 41: ...727 QFD Blue 728 Steel Green 729 Scuba Blue 730 Liberty Green 731 Dirty Ice 733 Damp Squib 735 Velvet Green 736 Twickenham Green 738 JAS Green 740 Aurora Borealis Green 741 Mustard Yellow 742 Bram Br...

Page 42: ...vapour 908 Xenon 909 Arena lighting 910 Frosty night 911 912 913 914 915 916 917 918 919 920 Fluorescent Warm White 921 Fluorescent Neutral White 922 Fluorescent Cold White 923 Fluorescent Old and gre...

Page 43: ...Overall Dimensions Rigging Centres LATEST VERSION AS OF JULY 2021 PANALUX SONARA 4 4 USER MANUAL 43...

Reviews: