Optical Characteristics
The waterfall diagram shows a typical spread of light when SONARA is suspended at various heights. Measurements were
taken with a temperature stabilised SONARA set at 3200K at maximum intensity.
Lux Variation With Height and Spread
Further detailed measurements listed below were taken with a SONARA at 3200K as above.
Sonara Luminous Intensity
Height
(m)
Lux (lx) at Spread (m)
Centre
1.2
2.4
3.7
4.9
6.1
7.3
8.5
9.8
11.0
12.2
3
2197
1859
1639
1420
1082
845
625
473
355
287
220
4
1236
1046
922
799
608
475
352
266
200
162
124
5
791
669
590
511
389
304
225
170
128
103
79
6
549
465
410
355
270
211
156
118
89
72
55
7
404
341
301
261
199
155
115
87
65
53
40
8
309
261
231
200
152
119
88
67
50
40
31