Connection
OM1305066E26
30
5.6 Using noise filter unit
●
Part list
●
Installation
(1) Connecting procedure varies with COM the signal wire
is connected to. (See the figure on the right.)
(a) Disconnect the signal wire from COM (A), wind it around
the clamp filter four turns, and then connect it to COM (A).
(b) Disconnect the signal wires from COM (A) and COM (B),
wind them around the clamp filter four turns, and then
connect them to COM (A).
(c) Disconnect the signal wire from COM (B), wind it around
the clamp filter, and then connect it to COM (A).
(2) Bind the clamp filter and the fixing plate and fix them
on the bottom plate of the controller.
Note
Check the following of the following phenomena occur.
The detector activates without a collision.
The servo turns off on its own during the welding operation in
program test mode.
A file closes on its own during the welding operation in program
test mode.
• Check if shielded cables are used.
• Check if the clamp filter is attached to the input/output signal
cable.
• Disconnect all input/output signal wires and then check if the
above phenomena still occur. If the same error occurs, please
consult your local Panasonic distributor.
No
Description
Q’ty
Note
1
Clamp filter
1
Accessories
2
Fixing band
1
3
Fixing plate
1
(1)
(3)
(2)