38
39
Configure event-related settings [Event setup] tab
Configure event-related settings such as the alarm output duration and buzzer duration.
■
Alarm action
Configure alarm-related items such as alarm output
duration and alarm auto reset.
[Output duration]
Select the output duration for the alarm signal output
from the terminal on the recorder’s rear panel when
an alarm occurs. When "0 s" is selected, alarm sig-
nals will not be output.
0 s/ 2 s/ 5 s/ 10 s/ 20 s/ 30 s/ 1 min
Ext.: Alarm output will continue until the alarm
action is reset. Refer to the "Cancel the alarm
action" (
☞
Page 125) for further information
about how to cancel the alarm action.
Rec.: Output of the alarm signal will continue dur-
ing event recording.
Default:
2 s
[Buzzer duration]
Set the duration of the buzzer sound when an alarm
occurs. When "0 s" is selected, the buzzer will not
sound.
0 s/ 2 s/ 5 s/ 10 s/ 20 s/ 30 s/ 1 min
Ext.: The buzzer will keep on sounding until the
alarm action is reset. Refer to the "Cancel the
alarm action" (
☞
mation about how to cancel the alarm action.
Rec.: The buzzer will keep on sounding during
event recording.
Default:
2 s
[Auto reset time]
Set the time for automatically resetting the alarm
action.
2 s/ 5 s/ 10 s/ 20 s/ 30 s/ 1 min/ 3 min/ 5 min
Ext.: The alarm action will not automatically reset.
Refer to the "Cancel the alarm action" (
☞
Page
125) for further information about how to can-
cel the alarm action.
Default:
Ext.
Note:
• If the time set for "Output duration" or "Buzzer
duration" is longer than that set for "Auto reset
time", the time set for "Auto reset time" will be
applied.
[Message display]
Select whether or not to display a message on a PC
connected to a network when an alarm occurs.
On: Display a message.
Off: Does not display a message.
Default:
On
[Emergency]
Set the frame rate of the emergency recording.
1 ips/ 3 ips/ 5 ips/ 10 ips/ 15 ips/ 25 ips/ 30 ips/
(Same as the basic)
Default:
Same as the basic
Note:
• If the rate of the basic settings is 50 ips or 60 ips, the
settings of the event recording and the emergency
recording will be the same as the rate or the basic
setting and displayed as "Same as the basic". In this
case, the settings of the event recording and
emergency recording cannot be changed.
[Referenced recording days] (
☞
[Back] button
Click the button after completing the settings. The
screen returns to the [Recording setup] tab.
[Setup via recorder's main monitor]