INSTALLATION (CONTINUED)
6
English
Secure conduit or stress relief to the opened knock-out hole. Refer to the wiring
diagram (page 4) and follow all local electrical safety codes as well as the National
Electrical Code (NEC). Using UL approved wire nuts, connect the conduit wires to the
unit wires.
5
6
Conduit
Neutral
Earth ground
Live
Earth ground
AC 120 V 60 Hz
(Power supply)
Neutral
Live
Use a Phillips head screwdriver to tighten the
screws clockwise into the device on the ceiling.
clockwise
7
Make sure the body of the product is
secured to the ceiling.
As you tighten the install screws, the install plates
will expand and fix themselves on the drywall.
CAUTION
1
While pressing the install plates upwards
and towards the body of the product,
carefully insert the device vertically into
the installation hole.
2
Rotate the product inwards to fit
properly onto the surface of the
drywall. Once inside the hole,
release the install plates.
Install plate
Install plate
Drywall
Install plate
Install plate
3
The install plates will position
themselves onto the drywall.
Install hole
Drywall
Rotate
Conduit
Install plate