80
12.3 Outdoor Unit
Attached accessories
Drain elbow
1
Rubber cap
7 (For WH-UD03JE5 and WH-UD05JE5)
No.
Accessories part
Qty.
3 (For WH-UD07JE5 and WH-UD09JE5)
1
2
Optional accessories
No.
Accessories part
Qty.
Base Pan Heater
CZ-NE2P (For WH-UD03JE5 and WH-UD05JE5 only)
1
• It is strongly recommended to install a Base Pan Heater (optional)
if the outdoor unit is install in cold climate area. Refer the Base Pan
Heater (optional) installation instruction for details of installation.
•
CZ-52F5,7,10BP
• Applicable Piping Kit (For WH-UD03JE5 and WH-UD05JE5)
CZ-4F5,7,10BP
CZ-NE3P (For WH-UD07JE5 and WH-UD09JE5 only)
Applicable Piping Kit (For WH-UD07JE5 and WH-UD09JE5)
3
12.3.1 Select the Best Location
If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat radiation from the
condenser is not obstructed.
Avoid installations in areas where the ambient temperature may drop below -20°C.
Keep the spaces indicated by arrows from wall, ceiling, fence or other obstacles.
Do not place any obstacles which may cause a short circuit of the discharged air.
If outdoor unit installed near sea, region with high content of sulphur or oily location (e.g. machinary oil, etc), it
lifespan maybe shorten.
If piping length is over 10 m, additional refrigerant should be added as shown in the table.
Model
Piping size
Pre-charged
Refrigerant
(kg)
Rated Length (m)
Max.
Elevation
(m)
Min. Piping
Length
(m)
Max.
Piping
Length
(m)
Additional
Refrigerant
(g/m)
Gas Liquid
For Heat
Pump
Indoor Unit
For
Hydromodule
+ Tank
WH-UD03JE5 and
WH-UD05JE5
ø12.7mm
(1/2")
ø6.35mm
(1/4")
0.90 7 7 20 3 25 20
WH-UD07JE5 and
WH-UD09JE5
ø15.88mm
(5/8")
ø6.35mm
(1/4")
1.27 7 7 30 3 50 25
Example: WH-UD03JE5
If piping length is 15m, the quantity of additional refrigerant should be 100g. [(15-10)m x 20 g/m = 100g]
12.3.2 Install the Outdoor Unit
12.3.2.1 Installation
Diagram
It is advisable to avoid more than 2 blockage directions. For better ventilation & multiple-outdoor installation,
please consult authorized dealer/specialist.
This illustration is for explanation purposes only.
10
0m
m
or
m
or
e
100
mm
or m
ore
10
00
m
m
or
m
or
e
300
mm
or m
ore
Vinyl tape (Wide)
Saddle
Indoor unit/Outdoor unit
connecting cable
Type designation 60245 IEC 57
or heavier cable
ø6.35mm (1/4")
Liquid refrigerant piping
ø12.7mm (1/2")
Gas refrigerant piping
10
0m
m
or
m
or
e
100
mm
or m
ore
10
00
m
m
or
m
or
e
300
mm
or m
ore
Vinyl tape (Wide)
Saddle
Indoor unit/Outdoor unit
connecting cable
Type designation 60245 IEC 57
or heavier cable
ø6.35mm (1/4")
Liquid refrigerant piping
ø15.88mm (5/8")
Gas refrigerant piping
(4-CORE WIRE/1.5 mm
2
)
For WH-UD03JE5 and WH-UD05JE5
For WH-UD07JE5 and WH-UD09JE5
(4-CORE WIRE/2.5 mm
2
)