21
Item Unit Outdoor
Unit
Pipe Diameter
Liquid
mm (inch)
6.35 (1/4)
Gas
mm (inch)
15.88 (5/8)
Standard Length
m (ft)
7 (23.0)
Pipe Length Range
m (ft)
3 (9.8) ~ 50 (164.0)
I/D & O/D Height Difference
m (ft)
30 (98.4)
Additional Gas Amount
g/m (oz/ft)
25 (0.3)
Refrigeration Charge Less
m (ft)
10 (32.8)
Compressor
Type Hermetic
Motor
Motor Type
Brushless (4-poles)
Rated Output
kW
1.70
Fan
Type Propeller
Fan
Material
PP
Motor Type
DC (8-poles)
Input Power
W
—
Output Power
W
60
Fan Speed
rpm
Cooling: 700
Heating: 580
Heat Exchanger
Fin material
Aluminium (Pre Coat)
Fin Type
Corrugated Fin
Row × Stage × FPI
2 × 30 × 19
Size (W × H × L)
mm
38.1 × 762.0 × 865.8 : 895.8
Power Source (Phase, Voltage, Cycle)
Ø Single
V 230
Hz 50
Input Power
Condition
(Ambient/Water)
A35W7 A7W35 A2W35
kW
Cooling: 2.21
Heating: 1.47
Heating: 2.01
Maximum Input Power For Heatpump System
kW
3.47
Power Supply 1 : Phase (Ø) / Max. Current (A) / Max. Input Power (W)
1Ø / 15.9 / 3.47k
Power Supply 2 : Phase (Ø) / Max. Current (A) / Max. Input Power (W)
1Ø / 13.0 / 3.00k
Power Supply 3 : Phase (Ø) / Max. Current (A) / Max. Input Power (W)
— / — / —
Starting Current
A
6.9
Running Current
Condition
(Ambient/Water)
A35W7 A7W35 A2W35
A
Cooling: 10.1
Heating: 6.8
Heating: 9.2
Maximum Current For Heatpump System
A
15.9
Power Factor
Power factor means total figure of compressor and
outdoor fan motor.
Condition
(Ambient/Water)
A35W7 A7W35 A2W35
%
Cooling: 95
Heating: 94
Heating: 95
Power Cord
Number of core
-
Length m
(ft)
-
Thermostat
Electronic
Control
Protection Device
Electronic Control