109
12.4.3.5 Service
Setup
34. Pump maximum speed
Flow rate
Max. Duty
Operation
88:8 L/min
0xCE
Select
35. Pump down
Service setup
17:26, Wed
Pump down:
ON
Con
fi
rm
ON
Con
fi
rm
OFF
36. Dry concrete
30°C
1
2
3
4
5
6
35°C
35°C
40°C
40°C
45°C
Stage
37. Service contact
ABC/ abc
A B C D E F G H I J K L M N O P Q R
S T U V W X Y Z
a b c d e f g h i
j k l m n o p q r s t u v w x y z
Select
Enter
Contact 1
Contact 2
Select
Con
fi
rm
Initial setting: Depend on model
Normally setting is not necessary.
Please adjust when need to reduce the pump sound etc.
Besides that, it has Air Purge function.
When *Pump
fl
ow setting is Max. Duty, this duty set is the
fi
x pump duty run
during room side operation.
Service setup
12:00am,Mon
Air Purge
Operate pump down operation
Service setup
Pump down:
12:00am,Mon
Pump down operation
in progress!
Operate concrete curing operation.
Select Edit, set temp for every stage (1~99 1 is for 1 day).
Setting range is 25~55°C
When it is turned ON, dry concrete starts.
When it is 2 zone, it dries both zones.
Able to set name & tel no. of contact
person when there is breakdown
etc. or client has trouble. (2 items)
Service setup
Service contact:
12:00am,Mon
Contact-1: Bryan Adams
0-9/ Other