53
Start with tank
mode first
Room thermo
OFF
Tank thermo
OFF (End)
Heat pump
thermo OFF
Solar
request ON
Go in tank interval
only after solar OFF
Switch to tank heat-up
when room thermo OFF
Heat pump OFF at room
side when room thermo
OFF and high tank temp.
Booster heater OFF
after achieve
tank temp.
On
Off
On
Off
3 ways valve
On
Off
Room Thermo
On
Off
Backup Heater
On
Off
Booster Heater
Water Pump
On
Off
On
Off
Solar Valve
On
Off
2 ways valve
On
Off
Solar Request
Heat Pump
T1
T2
T2
T1
T1
T2
T2
T1 = Back up heater delay time
T2 = Booster heater delay time