65
4. Room
Thermistor
Connect floor heating or radiator directly to Mono bloc.
Install separate external room thermistor (specified by Panasonic) in the room where floor heating is installed.
This is an application that uses external room thermistor.
There are 2 kinds of circulation water temperature setting method.
Direct: set direct circulation water temperature (fixed value)
Compensation curve: set circulation water temperature depends on outdoor ambient temperature
In case of Room thermo or Room thermistor, compensation curve can be set.
In this case, compensation curve is shifted according to the thermo ON/OFF situation.
(Example) If room temperature increasing speed is;
very slow
→
shift up the compensation curve
very fast
→
shift down the compensation curve
Max:
3
0m
Thermistor
Mono bloc compare between room temperature
and setting temperature on the Remote
controller to control HP and circulation pump.
Floor heating
Mono bloc
Setting of remote controller
Installer setting
System setup
Optional PCB connectivity - No
Zone & Sensor:
Room thermistor