64
12.2 Variation of system
This section introduces variation of various systems using Air-To-Water Heatpump and actual setting method.
12.2.1 Introduce application related to temperature setting.
Temperature setting variation for heating
12.2.1.1
1. Remote
Controller
Connect floor heating or radiator directly to the Mono bloc.
This is the basic form of the most simple system.
2. Room
Thermostat
Connect floor heating or radiator directly to the Mono bloc.
Install the remote controller in the room where floor heating is installed.
This is an application that uses remote controller as Room Thermostat.
3. External Room Thermostat
Connect floor heating or radiator directly to Mono bloc.
Install separate external Room Thermostat (field supply) in the room where floor heating is installed.
This is an application that uses external Room Thermostat.
Floor heating
Mono bloc
Setting of remote controller
Installer setting
System setup
Optional PCB connectivity - No
Zone & Sensor:
Water temperature
Mono bloc receive Room Thermo signal (ON/OFF) from
Remote controller to control HP and circulation pump.
There is a build-in thermistor in the remote controller.
Floor heating
Mono bloc
Setting of remote controller
Installer setting
System setup
Optional PCB connectivity - No
Zone & Sensor:
Room thermostat
Internal
Room thermostat
(Field supply)
Floor heating
Mono bloc
Setting of remote controller
Installer setting
System setup
Optional PCB connectivity - No
Zone & Sensor:
Room thermostat
(External)