15. Servicing
Guide
15.1 Open and Close Top Front Plate
1 Do not open or close the top front cabinet by excessive force.
2 Follow below illustrations to open / close the Top Front Plate.
15.2 How to take out Bottom Front Plate
Open and Close Bottom Front Panel
1 Must open the Top Front Plate before access Bottom Front Plate.
2 Remove the 5 mounting screws of Bottom Front Plate.
3 Slide it upwards to unhook the Bottom Front Plate hooks and slots.
4 Reverse above steps 1~3 for close it.
15.3 Test Run
1 Before test run, make sure below items have been checked:-
o
Pipework are properly done.
o
Electric cable connecting work are properly done.
o
Tank Unit is filled up with water and trapped air is released.
o
Please turn on the power supply after filling the tank until full.
o
In order to check whether the tank is full, switch heater once for about 10 min.
2 Switch ON the power supply of the Tank Unit. Set the Tank Unit RCCB / ELCB to “ON” condition. Then,
please refer to the Operation Instruction for operation of Control Panel.
3 For normal operation, Water Pressure Gauge reading should be in between 0.05 MPa and 0.3 MPa. If
necessary, adjust the Water Pump SPEED accordingly to obtain normal water pressure operating range. If
adjust Water Pump SPEED cannot solve the problem, contact your local authorized dealer.
4 After test run, please clean the Water Filter Set. Reinstall it after finish cleaning.
To Open
To Close
Open
“click”
Top Front Plate
Hold in
position
Close
“click”
CAUTION
When open or close the Top Front Plate, make
sure it is securely hold in position. Else, it may
fall and injures the fingers or palms.
Open or close the Bottom Front Plate carefully.
The heavy Bottom Front Plate may injures
the fingers.
Hook
Slot
3X
(screw)
2X
(screw)
Lever
Arm