
27
Dealer
Operation/settings to be done only by the authorised dealer/specialist.
User
Operation/settings to be done by the authorised dealer/specialist or user.
*
1
The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service partners.
*
2
Only displayed when COOL mode is unlocked (Means when COOL mode is available).
User
Control panel preparation
1
s
s
e
r
P
.
2
s
s
e
r
P
or
to set the current day.
3
Press
to confirm.
4
s
p
e
t
s
t
a
e
p
e
R
2
and
3
to set the current time.
■
Note:
:
w
o
l
e
b
s
e
s
a
c
n
i
t
e
s
e
b
o
t
d
e
e
n
e
m
it
d
n
a
y
a
d
t
n
e
rr
u
c
e
h
T
•
- When the power is turned on for the first time.
e
h
t
n
o
d
e
n
r
u
t
s
a
w
r
e
w
o
p
e
h
t
e
c
n
i
s
d
e
s
p
a
l
e
s
a
h
e
m
it
g
n
o
l
A
-
last time.
• The current time that has been set will be the standard time for
all the timer operations.
Caution Indicator (Tank Temperature above 60 °C)
6
Backup Heater For Tank
To activate backup heater during tank operation.
YES
YES
NO
• Do not use the system during sterilisation in order to prevent scalding with hot water, or overheating of shower.
• Ask an authorised dealer to determine the level of sterilisation function field settings according to the local laws and regulations.
7
Sterilisation
To sterilise the water tank, if required.
Note: If NO is selected, menus 8 to 10 are skipped.
YES
YES
NO
8
Sterilisation Day & Time
To set timer for sterilisation.
(Only once a week. Operates even under a standby condition)
Monday
12:00
Monday ~
Sunday
0:00 ~ 23:50
9
Sterilisation Temperature
To set the temperature of sterilisation.
65 °C
40 °C ~ 65 °C
10
Continuation of Sterilisation
To maintain heating temperature in order to complete the sterilisation.
10 minutes
5 minutes ~
1 hour
11
Base Pan Heater
To select whether or not to connect to the optional base pan heater.
Note: If NO is selected, menu 12 is skipped.
NO
YES
NO
12
Base Pan Heater type
Type A - The base pan heater activates only during deice operation.
t
n
e
i
b
m
a
r
o
o
d
t
u
o
n
e
h
w
s
e
t
a
vi
t
c
a
r
e
t
a
e
h
n
a
p
e
s
a
b
e
h
T
-
B
e
p
y
T
temperature is 5 °C or lower.
A
A
B
13
*
1,
*
2
Cool Outdoor Temperature setting
To set the outdoor ambient temperature for the AUTO mode to
change from HEAT to COOL.
15 °C
5 °C ~ 25 °C
14
*
1,
*
2
Heat Outdoor Temperature setting
To set the outdoor ambient temperature for the AUTO mode to
change from COOL to HEAT.
10 °C
5 °C ~ 25 °C
15
Dry Concrete
During construction to dry the concrete under a preset temperature.
Do not use this menu for any other purposes and in period other than
during construction (Refer to Information page).
-
1 day ~ 99 days
Summary of Contents for WH-ADC0916G9E8
Page 34: ...34 4 2 Outdoor Unit Air inlet rear Air inlet side Air inlet side Air outlet Air outlet ...
Page 40: ...40 8 Wiring Connection Diagram 8 1 Indoor Unit RY HT L1 RY HT L2 RY V3 RY V2 RY HT L3 ...
Page 100: ...100 Note Default value refer Location of Control and Component OPERATION ACTUAL ...