background image

Installation Guide

Note to the installer

■  Before attempting to connect or operate this product, please read the label on the rear of 

the main monitor.

■  Please read this guide carefully, and install the product safely and correctly by following 

the instructions. Carefully read the information found in the section titled "For your safety" 
in particular. 

■  Only use attachments/accessories specified by the manufacturer.
■  The installation shall be carried out in accordance with all applicable installation rules.
■  Panasonic assumes no responsibility for injuries or property damage resulting from failures 

arising out of improper installation or operation inconsistent with this guide. Additionally, 
any resulting malfunction will not be covered under the warranty.

■  After installation, make sure to leave this guide with the customer.

For the Installation of door station 

and main monitor station

• VL-V554BX is a surface mount type, VL-V554UBX 

is a flush mount type.

For your safety

To prevent severe injury and loss of life/property, read this section carefully before using the 
product to ensure proper and safe operation of your product.

WARNING

Preventing fire, electric shock and short circuits

 

● Leave installation work to the dealer. 

Installation work requires technique and experiences. Failure to observe this may 
cause fire, electric shock, injury, or damage to the product. Consult the dealer.

 

● Electrical connection work should be performed by certified personnel only. Certification 

is required for performing electrical connection work. Consult your dealer.

 

● Use only the specified power supply unit and AC cable.

 

● Do not attempt to disassemble or modify this product. Contact an authorised service 

centre for repairs.

 

● Never install wiring during a lightning storm.

 

● Do not connect non-specified devices.

 

● Do not connect a power cable to a terminal that is not specified in this guide.

 

● When opening holes in walls for installation or wiring, or when securing the power 

cable, make sure you do not damage existing wiring and ductwork.

 

● Do not make any wiring connections when the power supply is turned on.

 

● Do not use the supplied power supply unit for outdoor installations (it is for indoor use 

only).

 

● Do not install the main monitor and power supply unit in the following places:

 - Places where the main monitor and power supply unit may be splashed with water or 

chemicals.

 - Places where there is a high concentration of dust, or high humidity.

 

● Do not perform any actions (such as fabricating, twisting, stretching, bundling, forcibly 

bending, damaging, altering, exposing to heat sources, or placing heavy objects on the 
power cable) that may damage the power cable. Using the product with a damaged 
power cable may cause electric shock, short circuits, or fire. Contact an authorised 
service centre for repairs.

 

● When existing chime wires are used, it is possible that they contain AC voltage. 

Contact an authorised service centre.

 

● Do not install or use the product in health care facilities if any regulations posted in 

the area instruct you not to do so. Hospitals or health care facilities may be using 
equipment that could be sensitive to external RF (radio frequency) energy.

 

● Do not install or use this product near automatically controlled devices such as 

automatic doors and fire alarms. Radio waves emitted from this product may cause 
such devices to malfunction, resulting in an accident.

Preventing accidents and injuries

CAUTION

 

● If the wiring is underground, do not make any connections underground.

 

● If the wiring is underground, use a protection tube.

 

● If the wiring is outdoors, use a protection tube or a surge protector.

 

● Install the product securely adhering to the instructions in this guide to prevent it from 

falling off the wall. Avoid installing onto low-strength walls, such as gypsum board, ALC 
(autoclaved lightweight concrete), concrete block, or veneer (less than 18 mm thick) walls.

Preventing electric shock

Preventing injury

1-62, 4-chome, Minoshima, Hakata-ku, Fukuoka 812-8531, Japan

© Panasonic System Networks Co., Ltd. 2014

PNQW4430ZA   

C0814MM0

VL-V554BX/

VL-V554UBX

VL-MWD501BX

Door station

Main monitor station

Door station is described as "doorphone" 

and Main monitor station is described as 

"main monitor" in this guide.

Model No.

VL-SWD501AZ

VL-SWD501UAZ

Wireless Video Intercom System

Supplied accessories for installation

■  For the doorphone

Mounting 
base × 1 

(AZ only)

 

Flush 
mounting 
box × 1

(UAZ only)

Screw × 4 (Used when 
installing the doorphone)

(AZ   : 4 mm x 12 mm)
(UAZ : 4 mm x 25 mm)

Name plate × 2

(incl. 1 spare)

Hex wrench × 1

■  For the main monitor

 

Mounting 
bracket × 1

Cable binder × 1

Screw × 2 
(4 mm x 16 mm)

■  Power supply unit and related items

Power supply 
unit × 1

(Part No. VL-PS241)

AC cable × 1

Cable binder × 1

Screw × 2

(4 mm x 40 mm)

To avoid malfunction or communication disturbances, do not install the doorphone or the main 
monitor in the following locations:

 - Places where vibration or any other kind of impact occurs.
 - Places where echoing is frequent.
 - Places near a high concentration of dust, hydrogen sulphide, ammonia, sulphur, or noxious 

fumes.

■ 

For the doorphone

 

● If a strong light is shining on the doorphone, the visitor’s face may not be distinguishable. Do 

not place the doorphone in the following locations:

 - Where most of the background is the sky.
 - Where the background is a white wall, and direct sunlight will reflect off it.
 - Where direct sunlight will shine on the doorphone.

 

● Do not place the doorphone in locations where echoing occurs, as this will cause the 

doorphone to beep frequently.

 

● Dust protection/water protection is IP54. 

Only when installation work specified in this guide is properly performed and appropriate water 
protection treatment is performed.

 

● Make sure the rear of the doorphone is not subject to water.

 

● Depending on the installation location, condensation may form on the doorphone’s lens cover. 

This may cause images to become obscured. Condensation will dissipate as the temperature 
rises.

■ 

For the main monitor

 

● Install the main monitor away from electronic appliances such as TVs, radios, personal 

computers, air conditioners, boiler control panels with intercom, home security equipment, 
wireless devices, or digital cordless phones.

 

● Do not install the main monitor in places where it will be affected by extremely high-frequency 

radio waves (near broadcasting antennas etc.). This may cause the display to flicker or an 
interrupting noise to occur.

 

● Leave at least 20 cm of space above, below, and to the left and right sides of the main 

monitor. Do not install on a wall that is deeply recessed.

 

● Do not install the main monitor inside a wall.

 

● Be sure to install the main monitor more than 5 m away from the doorphone.

 

● The  product  operates  in  the  frequency  range  of  1.88  GHz  to  1.90  GHz,  and  the  RF 

transmission power is 250 mW (max.). Refer to the "For best performance" section in the 
Operating Instructions.

 

● In areas surrounded by a high electrical field, disturbances may occur in the main monitor’s 

image or sound.

Important:

 

You will need the following additional items to install and configure the doorphone 
and the main monitor. 
[Locally procured]

 - DC cable and wires (for doorphone and other connections): 

Prepare a cable and wires of the appropriate specification. (

 "Wire type and length")

Note:

 

● The illustrations in the supplied manual(s) may vary slightly from the actual product. 

Precautions for installation

Wiring schematic diagram

Set up correctly according to the following wiring schematic diagram and "Wire type and length".
●  For information, such as order numbers, about optional devices that can be connected to, refer to the "Additional/replacement accessories" section in the Operating Instructions.

MAIN MONITOR

DOORPHONE 1

DOORPHONE 2

POWER SUPPLY UNIT

Connection device for option output (A contact)

NP: Non-polarised

Power 

supply

Power 

supply

12 V AC/DC

12 V AC/DC

Electric lock

Electric lock

24 V DC

Wire type and length

Wiring run

Wire type

*1

Diameter

Length (Max.) 

Main monitor –

Doorphone

A

ø

 0.65 mm

22 AWG

100 m

ø

 1.0 mm

18 AWG

130 m

ø

 0.5 mm

CAT 5

50 m

Main monitor –

Power supply unit

B

ø

 0.65 mm

22 AWG

10 m

ø

 1.0 mm

18 AWG

20 m

Doorphone –
Electric lock

*2

C

ø

 0.5 mm - 

ø

 1.2 mm

(24 AWG - 17 AWG)

According to specifi-

cation of connected 

device.

Main monitor –

Connection device for option 

output (A contact)

*2

D

 

ø

 0.5 mm - 

ø

 1.2 mm

(24 AWG - 17 AWG)

According to specifi-

cation of connected 

device.

*1  Type: Single-pair cable with outer sheath (jacket)

Conductor: Copper solid

 

● A certified power supply wiring has to be used with this equipment. The relevant national 

installation and/or equipment regulations shall be considered. A certified power supply wiring 
not lighter than ordinary polyvinyl chloride flexible wiring according to IEC 60227 shall be used.

*2  When using an electric lock or a connection device for option output (A contact), select a device 

that meets the following guidelines:

 

● Electric lock connection terminal (S1/S2):

 - N/O dry closure contact
 - 12 V AC/DC, less than 1 A

 

● Connection device for option output (A contact) terminal (OUT1/OUT2):

 - 24 V AC/DC, less than 0.3 A (minimum contact: 5 V DC 1 mA) 

A

C

C

D

B

NP

NP

NP

NP

NP

NP

& screw × 2 
(3.8 mm x 20 mm)

Reviews: