1 by Multi  Video Intercom System

Installation Guide

1

Summary of Contents for VL-MWD501

Page 1: ...1 by Multi Video Intercom System Installation Guide 1 ...

Page 2: ...12 1 Specifications 2 1 Stylish Design P 14 2 2 Compact Design P 15 2 3 Customization with Each Module 1 P 16 2 4 Customization with Each Module 2 P 17 2 5 Customization with Each Module 3 P 18 2 6 Easy Accessible Name Plate P 19 2 7 Camera Angle P 20 2 8 E lock Access Control P 21 2 Features 3 1 VL MWD501 series P 23 3 2 VL MVN511 series P 24 3 3 VL MV10EX1 EX2 French Model P 25 3 4 Function Tabl...

Page 3: ...e Wiring P 33 4 6 Room No Setting Star Shape Wiring P 34 4 7 Setting for Distributer ID Bus wiring P 36 4 8 Room No Setting 1 Bus Wiring P 37 4 9 Room No Setting 2 Bus Wiring P 38 4 10 Room No Setting 3 Bus Wiring P 39 4 11 Room No Setting 4 Bus Wiring P 40 4 12 Wiring Power Supply Unit Bus Wiring P 41 4 13 Install Lobby Station P 42 4 14 Bundled Items P 43 4 Installation 5 Appendix 3 ...

Page 4: ...1 Specifications 4 ...

Page 5: ...rees H 170 degrees V 115 degrees Lighting method White color LED White color LED Minimum illuminance 1 lx 1 lx Calling I F Calling Method Back lighting Direct Call Button Name plate access from front side White color LED Call by input Key Room Number or selecting List of Phone book White color LED CCTV Security Camera Control Box PBX Lift Controller Terminal Distribution Box Distribution Box Door ...

Page 6: ...U Call Talk E lock open Monitoring up to 32 room monitors E lock Vigik A C Room Monitor E lock Vigik A C Call Talk E lock open Monitoring Panasonic system is only available for both wiring topology PSU 2 2 2 2 2 2 2 3rd Party 3rd Party Some Power Supply Units PSUs are abbreviated in figures The configuration of PSUs depends on system requirement and specification of devices selected in each system...

Page 7: ... VL VM303 4 Button Module VL VM304 Surface Mount Cover Smaller Type VL VM502 Surface Mount Cover Large Type VL VM503 Back Box Small Type VL VM602 Back Box Large Type VL VM603 Blank Panel VL VM901 Distributor VL VM701 High Power Type PSU VL PS2410 Room Monitor VL MWD501 VL MVN511 VL MV10EX Vigik Panel VL VM902 Extension Cable VL VM801 Vigik module is sold by 3rd party 7 PSU VL PS240 ...

Page 8: ...dule VL VM304EX 4 buttons module VL VM502EX Surface Mount Cover Small Type Cover for surface mount VL VM503EX Surface Mount Cover Large Type VL VM602EX Back Box Small Type Flush mount box VL VM603EX Back Box Large Type VL VM901EX Blank Panel Half module size Panel for unfilled space VL VM902EX Vigik Panel Half module size VL VM801 Extension Cable Cable for extension VL VM701EX Distributer Distribu...

Page 9: ...e name plate Inaccessible type is also available White coloured LED lights for night colour vision with illuminance sensor The life of a Key backlight LED 23 years Status Indicators Calling Talking Door Opening Audio guidance for DDA Door opening EN FR DE ES IT NL AR FA IP55 IK08 Aluminum panel Connectable devices Role of the Lobby Station Door entry panel for the public entrance of housing comple...

Page 10: ... 7 Vigik module input 8 K OUT for NC NO 1 Specifications 1 6 Lobby Station 2 5 1 2 4 3 9 Dip switch for setting 10 Connector cable for module connection 11 Connector for DDA module TBD 12 Connector for 12key module TBD 13 Power switch 14 Terminal for DC in 15 K IN 16 Terminal foe star shape wiring 9 10 13 14 15 16 6 7 8 11 12 10 ...

Page 11: ...room monitors can be connected per a distributor Powered by PSU PS240 or PS2410 or bus powered by previous distributor 5 3 4 2 6 9 8 7 1 1 Terminal for DC in 2 DIP SW for distributor ID 3 Terminal for bus wiring input 4 Terminal for bus wiring output 5 DIP SW for Line1 Room No 6 Terminal for Line1 7 Terminal DIP SW for Line2 8 Terminal DIP SW for Line3 9 Terminal DIP SW for Line4 11 ...

Page 12: ...40 VAC Output 24 VDC 2 5A Up to 6 outputs Total output current 2 5A Mountable on a DIN rail or attach to a wall directly 1 3 4 5 6 7 8 9 2 1 Power Switch 2 Terminal for Ground 3 Terminal for AC input 4 Terminal for DC output 1 5 Terminal for DC output 2 6 Terminal for DC output 3 7 Terminal for DC output 4 8 Terminal for DC output 5 9 Terminal for DC output 6 12 ...

Page 13: ...2 Features 13 ...

Page 14: ...3 Features 2 Features 2 1 Stylish Design Stylish Lobby Station Hairline Finish Compact Design Big Button LED Indicator 14 ...

Page 15: ...than existing one Panel size Possible Impossible to fix Installers prefer small lobby wall print Space saving Problem of the smaller lobby station Panasonic F company 8 button type A company Name Plate is big But there are only 4 buttons There are 8 buttons But button and name plate is small Big buttons combined with front accessible name plates 15 ...

Page 16: ...s 2 Features 2 3 Customization with Each Module 1 It is possible to select according to the customer requirement VL VM101 VL VM503 VL VM302 VL VM303 VL VM304 VL VM301 VL VM603 VL VM901 Fully configured system 16 ...

Page 17: ...Size Half Module Size Half Module Size Full Module Size Half Module Size Half Module Size Small size Back Box configuration example Camera Module VM101 full 1 pc 4 button module VM304 half 1 pcs Blank Panel VM901 half 1 pc Large size Back Box configuration example Camera Module VM101 full 1 pc 4 button module VM304 half 3 pcs Blank Panel VM901 half 1 pc 17 ...

Page 18: ...es 2 Features 2 5 Customization with Each Module 3 It is possible to select according to the customer requirement 1 When the flush mount installation method is used a Surface Mount Cover cannot be installed 18 ...

Page 19: ...to remove Change the name plate Factor To change the name plates have to remove the panel and access to rear side Manager Just changing name plates does not generate profit Not comfortable to ask installers just to change name plates Installer Adopt the front accessible name plates Using the screw it prohibit to remove the name plate 19 ...

Page 20: ...age Approx 90 The face can be seen regardless of height and posture Almost the full width is visible Industry average Approx 70 Approx 170 Approx 110 The wide angle camera gives a wide view of the front porch area If lobby station installed vertically toward the door it is difficult to catch the visitor by standard angle camera door door Standard angle Wide angle Difficult to catch the face Possib...

Page 21: ...ntrol Card Reader Outside Electrical Lock Access Control Card Reader Outside 2 N P K OUT K OUT S1 and S2 Normally Open Active Close S2 and S3 Normally Close Active Open Wiring Schematic K IN 2 N P Switch Inside K IN C1 and C2 Access Controller input C3 and C4 Open Door sensor input DC IN L IN L1 L2 DIP SW K OUT To AC power outlet Open Door sensor Input To Distributor Power Supply K IN 2 N P 21 ...

Page 22: ...3 Monitor Line Up 22 ...

Page 23: ...sub monitor Answer visitors in anywhere at home Support additional sub monitors up to 6 2 Super wide angle camera Wide view with horizontal 170 degree Easy and smooth zoom Clear view LED light in night time Support E lock connection from door camera Support extend of wireless range by DECT repeater 3 Features 3 Monitor Line Up 3 1 VL MWD501 Series Product image Option output A contact Lobby Statio...

Page 24: ...e connectivity 2 Picture recording function Option Connectivity Easy setup Easy install with Wi Fi connection Up to 50 pictures recordable Door station Lobby Door station Repeater Digital PBX Product image Relay unit VL RLY1 Power supply unit for VL MWD511 Wireless router Smartphone Lobby Station Option input A contact App PSU Up to 4 PSU 2 1 1 Relay Box VL RLY1 is NOT included with a single unit ...

Page 25: ... No external Power Supply Unit Contribute to reduce system price Power is provided by the bus line or a lobby station Easy to install Status indicators LED 3 5 inch LCD display Door Bell 3rd Party Main Monitor VL MV10EX1 Main Monitor VL MV10EX2 French Model 25 Lobby Station Option output A contact PSU Product image Power Source Supplied by the bus line or a lobby station Devices that can be connec...

Page 26: ...ure recording Y Up to 400 images Up to 50 visitors 8 shots per visitor Y Up to 400 images Up to 50 visitors 8 shots per visitor Voice changer Y Y Wireless monitor Y Up to 6 Repeater Y Up to 2 Smartphone connect Y Up to 4 E mail notification Y Up to 4 1 Wireless sensor camera Y Up to 4 VL WD812 Intercom call Y 2 Door unit Door Station VL V554 VL V554U VL V555 VL V522L Door Station VL V554 VL V554U ...

Page 27: ...4 Installation 27 ...

Page 28: ...ications 4 Installation Step 1 Attach the every modules to the frame Need to attach upper side module first Step 2 Connect each modules by wire connector Put the module cable cover on each Wire connector 4 1 Lobby Station Assembly 1 28 ...

Page 29: ... Long connector cable for surface mount 1 Connect camera module with 1st button module 2 Connect 1st button module with 2nd button module 3 Connect 2nd button module with 3rd button module Detail for connector cable Repeat this procedure to last button module Multi panel cabling Cable VL VM801 option Surface mount cover is required Camera module side Camera module side Cable length TBD Ensure the ...

Page 30: ... 7 0010 Italian bit 4 7 1010 Dutch bit 4 7 0110 Arabic bit 4 7 1110 Persian bit 4 7 0001 Monitoring from R M Enable Monitoring bit8 0 Disable Monitoring bit8 1 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 ...

Page 31: ...e the riser to wire the bus Wiring distance Lobby Station Room Monitor Max 100m φ0 65 Max 200m φ1 20 Wiring distance Lobby Station Distributor Max 100m φ0 65 Max 200m φ1 20 Distributor Room Monitor Max 100m φ0 65 Max 200m φ1 20 Example System configuration of Bus powered type Monitors in figures The configuration of PSUs depends on system requirement and specification of devices selected in each s...

Page 32: ...Star Shape Wiring 32 ...

Page 33: ...deo Intercom Product 2 Specifications 4 5 Wiring Power Supply Unit Star Shape Wiring 4 Installation 2 2 Room monitor is connected with button module Lobby Station Normal type PSU VL PS240 Room Monitor AC 33 ...

Page 34: ...tions 4 6 Room No Setting Star Shape Wiring 4 Installation No setup required John Smith Star shape wiring Each room monitor are connected to the button directly John Smith David Brown David Brown Room Monitor Lobby Station Room Monitor 34 ...

Page 35: ...Bus Wiring 35 ...

Page 36: ...Intercom Product 2 Specifications 4 7 Setting for Distributor ID Bus wiring 4 Installation Distributor ID 1 Distributor ID 4 Distributor ID 5 Distributor ID 6 Distributor ID 7 Distributor ID 3 Distributor ID 8 Distributor ID 2 1 2 3 4 5 6 7 8 OFF 1 2 3 4 5 6 7 8 OFF 1 2 3 4 5 6 7 8 OFF 1 2 3 4 5 6 7 8 OFF 1 2 3 4 5 6 7 8 OFF 1 2 3 4 5 6 7 8 OFF 1 2 3 4 5 6 7 8 OFF 1 2 3 4 5 6 7 8 OFF ON ON ON ON O...

Page 37: ... Room No Setting 1 Bus Wiring 4 Installation Need to set the room number on each distributor Bus wiring John Smith David Brown John Smith David Brown Each room monitor are connected to distributor randomly Distributor Room Monitor Lobby Station 37 ...

Page 38: ...The button number is fixed on lobby station from 1 to 32 John Smith David Brown John Smith David Brown 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Set the DIP switch to Room No 20 Set the DIP switch to Room No 30 DIP switch for room number setting 38 ...

Page 39: ...tton 8 bit1 6 000100 Button 9 bit1 6 100100 Button 10 bit1 6 010100 Button 11 bit1 6 110100 Button 12 bit1 6 001100 Button 13 bit1 6 101100 Button 14 bit1 6 011100 Button 15 bit1 6 111100 Button 16 bit1 6 000010 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 ...

Page 40: ... 6 110110 Button 28 bit1 6 001110 Button 29 bit1 6 101110 Button 30 bit1 6 011110 Button 31 bit1 6 111110 Button 32 bit1 6 000001 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 O...

Page 41: ...ibutors by normal type PSU VL PS240 Normal type PSU VL PS240 2 2 or Room monitor is connected with distributor Up to 8 distributors by high power type PSU VL PS2410 Additional normal type PSU VL PS240 for 4 distributors Lobby Station Distributor Room Monitor 2 AC Power Supply Unit PSU AC AC AC 41 ...

Page 42: ... Lobby Station 4 Installation Flush Mount Surface Mount 2 Install the lobby station 1 Fix the mount box into the wall 1 Fix the mount box onto the wall 2 Install the lobby station Surface mount cover is required 42 ...

Page 43: ...lation Spare Button Middle length cable is bundled to camera module Connector Cable Short length cable is bundled to button module Spare buttons are bundled to button module 43 Button qty Spare qty 1 Button module 1 pc 2 Button module 3 Button module 2 pcs 4 Button module ...

Page 44: ...5 Appendix 44 ...

Page 45: ...ightly from photograph All pictures of the LCD display are simulated Weights and dimensions are approximate Design and Specifications are subject to change without notice These products may be subject to export control regulations 45 ...