– 79 –
Chapter 9 Other Useful Functions — Setting the time data
Reference time code
<GENLOCK IN> terminal
<TC IN/OUT> terminal
Reference video signal
External lock operation procedure
To externally lock the time code, follow the steps below.
1
Press the <TC> button to display the TC screen.
2
From the time code display, select [Free Run] in [Free/Rec].
3
From [MENU]
→
[REC SETTINGS]
→
[TC]
→
[TC IN/OUT SEL], select [TC IN].
4
Enter the external time code from the <TC IN/OUT> terminal.
[SLAVE] is displayed on the TC screen.
The [TCG] characters on the HOME screen are displayed in black and white inversion.
f
For the reference video signal, enter the SDI signal which is the same format as the system signal format ([FREQUENCY], [PIXEL]).
f
When the system frequency is 59.94p or 50p, the time code may be out of sync by one field.
f
When the input reference signal of generator lock is disrupted, recording cannot be performed normally. [TEMPORARY PAUSE IRREGULAR SIG]
is displayed in the viewfinder screen, and the clip is divided. The synchronization with the time code is also not guaranteed. Recording will resume
when the signal returns to normal.
f
When the time code is externally locked, the time code is instantaneously locked to the external time code, the same value as the value of the
external time code is output to the counter display area. Do not set to the recording mode for several seconds until the sync generator has
stabilized. Furthermore, lock the time code to the <TC IN/OUT> terminal signal.
f
If you execute the slave once, even if there is no longer <TC IN/OUT> terminal and <GENLOCK IN> terminal input, the slave status is maintained.
However, in the following cases, the slave status will be released.
-
When [TC SET] is executed
-
When the power is turned off
-
When switched [DF]/[NDF]
-
When set to [Rec Run]
-
When a variable frame rate is applied
f
The SDI input time code cannot be slave-locked (synchronized).
f
If [EXT INPUT] is selected in [UB MODE] of the UB screen, regardless of the time code slave status, the user bits can be matched with the user
bits input in the <TC IN/OUT> terminal. In this case, [UBG] characters are black and white inverted.
Cautions when switching the power supply from the battery to the external power supply while an external lock is
active
To keep on the time code generator power supply continuously, connect an external power supply to the <DC IN> terminal and then remove the battery
pack. If the battery pack is removed first, there is no guarantee that the time code will stay externally locked.
Supplying the time code externally
You can supply the output time codes to an external recording device from the camera by matching the camera images or the replayed images.
Summary of Contents for Vericam 35
Page 1: ...35 Operating Guide W1014HM0 YI VQT5K88A E ...
Page 5: ...Before using the camera read this chapter Chapter 1 Overview ...
Page 65: ...This chapter describes video output Chapter 8 Output and Screen Display ...
Page 113: ...This chapter describes the specifications of this product Chapter 12 Specification ...
Page 118: ...Index 118 Z Zebra patterns 63 ...