– 30 –
Chapter 3 Preparation — Connecting to the DC output terminal
Connecting to the DC output terminal
Connecting the <DC OUT/RS> terminal to the external recording start/stop switch
It is possible to get a 1.0 A current from the <DC OUT/RS> terminal of the recording module.
Recording start/stop can be controlled by connecting an external switch to this terminal.
An LED connected to this terminal can also be used as a tally lamp. This is useful for shooting video when fixing the camera on a crane.
1
2
3
4
<DC OUT/RS> terminal
LED
Resistance
start/stop
(Connection example)
Cable connector
HR10A-7R-4SC (73)
Hirose Electric Co.
Recording
1 GND
2 TALLY OUT
Open collector output on the camera side
Tally lamp on
Low impedance
Tally lamp off
High impedance
3 Recording start/stop switch
This is connected in parallel to the <REC> button on the camera or the VTR button on the lens.
4
+
12 V
@
@
NOTE
t
Make sure that polarity is correct before connecting an external device. Otherwise, it may result in a malfunction.
Connecting to the <DC OUT> terminal
It is possible to get a 1.0 A current from the <DC OUT> terminal of the camera module.
1
2
Cable connector
0B.302
LEMO
1 GND
2
+
12 V
@
@
NOTE
t
Make sure that polarity is correct before connecting an external device. Otherwise, it may result in a malfunction.
Summary of Contents for Vericam 35
Page 1: ...35 Operating Guide W1014HM0 YI VQT5K88A E ...
Page 5: ...Before using the camera read this chapter Chapter 1 Overview ...
Page 65: ...This chapter describes video output Chapter 8 Output and Screen Display ...
Page 113: ...This chapter describes the specifications of this product Chapter 12 Specification ...
Page 118: ...Index 118 Z Zebra patterns 63 ...