– 113 –
Chapter 10 Menu Operations — Menu list
Item
Description of settings
[EXT.FUNC]
[FOCUS DISP]
Sets the unit that displays the focus distance.
[Meter], [Feet]
f
Factory setting: [Feet]
[LENS SETTING]
[A.IRIS TYPE]
Determines whether to set the speed control to the lens volume and use the value set in the menu.
[LENS], [CAM]
f
Factory setting: [LENS]
[A.IRIS LEVEL EFFECT] Sets the target value during auto iris operation.
[0] - [100]
f
Factory setting: [30]
[A.IRIS SPEED]
Sets the speed when the [A.IRIS TYPE] is set to [CAM].
[1] - [20]
f
Factory setting: [10]
[A.IRIS WINDOW]
Selects the auto iris detection window.
[NORMAL1]:
Window that is near screen center.
[NORMAL2]:
Window that is near screen bottom.
[CENTER]:
Window that is a spot in the screen center.
f
Factory setting: [NORMAL1]
[A.IRIS PEAK/AVE]
Sets the ratio included in the peak for auto iris standard.
[0] - [100]
f
Factory setting: [30]
[LENS CONNECT
TYPE]
Sets the type of lens to be connected.
[TYPE A]:
Lens controlled with LDS (Lens Data System). (ULTRA PRIME lens not supported)
[TYPE B]:
Lens controlled with 12-pin connector
[TYPE C]:
Lens controlled with cooke/i communication
[OFF]:
Other lenses
f
Factory setting: [OFF]
[REC SETTINGS]
The various setting items of the recording function of the camera.
Item
Description of settings
[FILE NAME STYLE]
Sets the file name style.
[CINE]:
Records a file as a file name of cinema style.
For details, refer to “File name style” (page 34).
[P2]:
Records a file as a file name style unique to P2.
f
Factory setting: [P2]
[REC FUNCTION]
[REC MODE]
Selects the special recording function.
[NORMAL]:
Normal recording
[INTERVAL]:
Interval recording (function to perform intermittent recording in constant interval)
[ONE SHOT]:
One-shot recording (function to perform recording of specified duration every time the REC
button is pressed)
The setting is fixed to [NORMAL] when [SYSTEM SETTINGS]
→
[MON OUT INDICATOR]
→
[VFR] is set
to [ON].
f
Factory setting: [NORMAL]
[REC TIME]
Sets the recording duration of single one-shot recording.
[00s01f]…[59s23f]
f
The maximum value of the frame digit differs depending on the system frequency.
f
Factory setting: [00s01f]
[INTERVAL TIME]
Sets the intermittent recording frequency of single interval recording.
[0h00min00s02f]…[1h00min00s00f]
f
Factory setting: [0h05min00s00f]
[START DELAY]
Sets the delay time to start recording for the interval recording and the one-shot recording.
[0s]…[10s]
f
Factory setting: [0s]
[PRE REC MODE]
Selects the pre-recording (function to record few seconds earlier than when the REC button is pressed by
accumulation into the internal memory).
[ON], [OFF]
The setting is fixed to [OFF] when [REC MODE] is set to [INTERVAL] or [ONE SHOT].
f
Factory setting: [OFF]
[FILE SPLIT]
Sets whether to split the recording file by units of 4 GB or just maintain one file, when the following two
conditions are met:
f
When OP-1b format codec is selected in [MENU]
→
[SYSTEM SETTINGS]
→
[SYSTEM MODE]
→
[MAIN CODEC]/[SUB CODEC].
f
When the recording size exceeds 4 GB
[ONE FILE]:
Records in one file.
[SPLIT]:
Splits the clip every 4 GB.
f
Factory setting: [ONE FILE]
When [MAIN CODEC] is set to OP-Atom format, [SUB CODEC] will also be fixed to [SPLIT]. When [MAIN
CODEC] is set to [ProRes 422 HQ] or [ProRes 4444], it will be [ONE FILE] regardless of the setting.
Summary of Contents for Varicam 35
Page 1: ...35 Operating Guide Version 6 W1014HM6056 YI VQT5K88A 6 E ...
Page 5: ...Before using the camera read this chapter Chapter 1 Overview ...
Page 73: ...This chapter describes video output Chapter 8 Output and Screen Display ...
Page 162: ...Maintenance and warning system of the camera are described Chapter 14 Maintenance ...
Page 168: ...This chapter describes the specifications of this product Chapter 15 Specification ...
Page 174: ...Web Site http www panasonic com Panasonic Corporation 2014 ...