93
UF-5500 / 4500
10.1.2. Service Mode 1 (Function Parameter Setting)
Use the following procedure to change the function parameters.
Note:
The following buttons provide these functions in the Service Mode:
Service Mode 1
Step
Operation or Unit Condition
LCD Display
(The pictured model is UF-5500.)
1
Standby
2
Press “FUNCTION” and then “7”.
3
Press “MONITOR” four times, then press “*”.
4
Enter the key operator password (The factory default ID is 00000000.) and press
“Set”.
5
Press “1”.
6
Enter the Function Parameter Number.
Ex: Changing the "ALARM STATUS" -- Enter "001" and press [SET].
7
Press “START”.
8
Enter the new setting value. Ex: Enter "3" for Constant.
9
Press “START”. The new value will be stored and the next parameter will be
displayed.
10
Repeat steps 5 through 8 to change other Function Parameters or Press “STOP”
twice to return to standby.
“START”
: The new setting value is stored in the machine.
“V”
: Scroll the function parameter number down.
“/\”
: Scroll the function parameter number up.
MMM-dd 15:00
00%
SET MODE (1-8)
ENTER NO. OR
SERVICE MODE ID:
ENTER ID=
SERVICE MODE
ENTER NO. OR
PARAMETER
ENTER PARAM. #_
PARAMETER #001
ALARM STATUS?
ALARM STATUS:
Timer<>
ALARM STATUS:
Const.<>
PARAMETER #002
STOP COMM.JRNL?
MMM-dd 15:00
00%
Summary of Contents for UF-5500
Page 180: ...180 UF 5500 4500...
Page 248: ...248 UF 5500 4500 13 5 Test Chart 13 5 1 ITU T No 1 Test Chart...
Page 249: ...249 UF 5500 4500 13 5 2 ITU T No 2 Test Chart...
Page 281: ...281 UF 5500 4500 10 10 11 15 12 17 18 19 20 21 22 23 24 28 29 30 27 25 26 21 13 14 16 30...
Page 287: ...287 UF 5500 4500 130 131 132 133 134 135 136 137 138 139 140 141 PCB2 A UF 5500 only CN1...
Page 297: ...297 UF 5500 4500...
Page 305: ...305 UF 5500 4500...
Page 311: ...311 UF 5500 4500 501 502 503 504 506 507 505 508 509 511 510 514 513 512 P51 P53 P54 A51 P52...
Page 362: ...362 UF 5500 4500...