11.3.4. Information Code: 416
CROSS REFERENCE:
START
END
Is communication with the
reference unit successful?
Change Function Parameter
#011: Reduce Rx Sensitivity
Level
Yes
No
Yes
No
Change Function Parameter
#023: Increase Training
Check Period
Does the problem still occur?
Replace the MAIN PCB.
Refer to
Sect. Communications.
Does the problem still occur?
Change Function Parameter
#013: Increase G3 Rx
Equalization
Does the problem still occur?
END
Does the problem still occur?
Yes
No
No
Yes
No
Yes
Check the telephone line